Manitowoc Ice K00017 User Manual

Manitowoc Ice Freezers

Advertising
background image

K00017 STACKING KIT

Installation Instructions

1. The K00017 stacking kit is used for stacking an E-0400

on an E-0600 ice machine. The bin must be leveled
before proceeding. NOTE: THIS STACKING KIT IS
ALSO USED, WHEN STACKING G-0600 ON G-0800
ICE MACHINES.

2. INSTALLATION OF E-0600 ICE MACHINE:

A. See service manual for uncrating and inspection of

ice machine.

B. Remove top cover from ice machine (NOTE: do not

put screws back in.).

C. Set ice machine carefully and squarely on bin.
D. Position shim angle, provided in kit, on right side, as

shown in Illustration 1.

E. Add foam tape, as shown in Illustration 1.
F. With four screws, install top cover from kit on left

side of ice machine (NOTE: flange goes over side
panel.).

G. Remove right-hand side panel.

3. INSTALLATION OF E-0400 ICE MACHINE:

A. See service manual for uncrating and inspection of

ice machine.

B. Remove right-hand side panel and bottom four

screws on left-hand side panel.

C. Set E-0400 ice machine on E-0600 ice machine with

right-hand sides in line (NOTE: flange on top cover
should be inside left-hand side panel.).

D. Install four screws in bottom left-hand side panel.
E. Bolt right-hand sides of ice machines together with

1/4-20 x 5/8” long bolt, lock washer, and nut,
provided in kit.

F. Reattach right-hand side panels.

4. INSTALLATION OF WATER SHIELD:

A. Remove angle “A”, the water pump, float valve

bracket assembly, and sump trough from top ice
machine.

B. Remove existing sheet metal screw at lower right

corner of bulkhead below siphon tube. Locate water
shield above the lower machine’s electrical box. Use
existing screw to fasten flange of shield to bulkhead.
Apply RTV sealant to the top edges of flange to
provide a watertight seal.

C. Reinstall the sump trough, float valve bracket

assembly, and water pump.


5. INSTALLATION OF ICE CHUTE:

A. Remove the ice chute from kit and set bottom

mounting brackets over angle “B” on E-0600 ice
machine (Illustration 3).

B. Put angle “A” in slots of top mounting brackets and

secure in place.

C. Check for free movement of water curtains.
D. Proceed to ice machine service manuals for electrical

and water hook-up and start-up procedure.












Manitowoc Ice, Inc.

2110 South 26 Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA
Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879 8001403
Web Site -

www.manitowocice.com

Rev. 05/11/01

Advertising