Self-contained electrical wiring connections, For united kingdom only, Warning – Manitowoc Ice S1000M User Manual

Page 12

Advertising
background image

Installation Instructions

Section 2

2-4

Part Number 80-1561-3

Self-Contained Electrical Wiring Connections

SELF CONTAINED ICE MACHINE

115/1/60 OR 208-230/1/60

SELF CONTAINED ICE MACHINE

208-230/3/60

SELF CONTAINED ICE MACHINE

230/1/50

!

Warning

These diagrams are not intended to show proper
wire routing, wire sizing, disconnects, etc., only the
correct wire connections.
All electrical work, including wire routing and
grounding, must conform to local, state and national
electrical codes.
Though wire nuts are shown in the drawings, the ice
machine field wiring connections may use either
wire nuts or screw terminals.

L

1

L

1

N=115V

OR

L2=208-230V

GROUND

GROUND

ICE MACHINE

CONNECTIONS

SV1258

TO SEPARATE

FUSE/BREAKER

L

1

L

1

GROUND

GROUND

ICE MACHINE

CONNECTIONS

TO SEPARATE

FUSE/BREAKER

L

2

L

3

L

2

L

3

SV1190

L

1

L

1

N

N

GROUND

GROUND

ICE MACHINE

CONNECTIONS

TO SEPARATE

FUSE/BREAKER.

DISCONNECT ALL

POLES.

SV1191

For United Kingdom Only

As the colors of the wires in the mains lead of the appliance may not correspond with the colored markings
identifying the terminals in your plug, proceed as follows:

The wire which is colored green and yellow must be connected to the terminal in the plug which is marked with
the letter E or by the earth ground symbol

or colored green or green and yellow.

The wire colored blue must be connected to the terminal which is marked with the letter N or colored black.

The wire colored brown must be connected to the terminal which is marked with the letter L or colored red.

Advertising