Mts-4a c, Rray, Esign – Meyer Sound MTS-4A User Manual

Page 11: Requencies, Oading, Overage, Aximum

Advertising
background image

A

RRAY

D

ESIGN

FOR

L

OW

F

REQUENCIES

Since the MTS-4A contains sub and low frequency drivers, in
addition to mid and high drivers, array design for the MTS-4A
must incorporate the different array response of high and low
frequencies. The beam width for a single speaker widens as
the frequency decreases. Frequencies below 125 Hz are mostly
omnidirectional while higher frequencies are more directional.

NOTE: H and V are abbreviations for horizontal and vertical.

The low frequencies of adjacent arrayed speakers exhibit
on-axis addition and off-axis cancellation, resulting in a
narrowing of coverage in the dimension in which they are
arrayed. A H array of two MTS-4As narrows the H coverage
without affecting the V coverage. A V array of two MTS-4As
narrows the V, without affecting the H coverage. In both
cases, there is 3 to 6 dB SPL of on-axis low frequency (LF)
addition compared to a single MTS-4A. Due to the larger
distance between LF drivers in V, compared to H arrays, the
V coverage narrows at a faster rate than does the H coverage
for H arrays, given the same array size and adjacent speaker
placement.

Increasing the number of MTS-4As in the array increases the
LF directional control. A properly designed V array steers
low frequencies to include balconies and upper tiers, while
a H array focuses low frequencies for longer throw distances
without interacting with the walls.

L

OADING

One of the most important factors governing LF response is
speaker placement with respect to adjacent surfaces. The MTS-
4A gains significant LF power by coupling with nearby floors
and walls. Half-space loading describes a speaker coupling
with one surface. Speakers placed on the floor benefit
from half-space loading, while flown speakers in free-space

(without a nearby wall or ceiling) do not. In general,
subwoofers in half-space generate twice the SPL (+6 dB)
compared to the same number in free-space.

NOTE: SPL values refer to an on-axis measurement position.

The actual SPL addition and narrowing of coverage
varies with frequency and depends on the physical
displacement between cabinets, loading conditions, and
room acoustics.

MTS-4A C

OVERAGE

AND

M

AXIMUM

SPL

A series of outdoor tests was conducted at Meyer Sound to
determine the coverage angle and on-axis SPL for arrays with
one and two horizontal rows of up to five speakers each, at
numerous splay angles. The measurements were conducted at
a distance of 8 m with half-space loading; on-axis SPL values
were interpolated from 8 to 1 m. The coverage angle for the
array is the result of averaging the –6 dB points from 125
Hz to 8 kHz.

The horizontal angles in the tables below represent the
optimal narrow (15°), middle (30°), and wide (45°)
orientations for the MTS-4A. The vertical splay angles
represent the optimal narrow and wide configurations. 2@0°
LT denotes long throw: the two horns are coupled directly
together (top speaker upside down/bottom speaker upright) to
form a single narrow horn.

The table on this page shows the SPL and coverage angles
that result from grouping the MTS-4A in arrays of up to five
units horizontally and two rows vertically. All splay angles
refer to the angle between cabinet centers.

If this information does not address your application
requirements, contact Meyer Sound to obtain additional
information on array design.

MTS-4A Array Coverage and Maximum SPL

Number of Horizontal

MTS-4As @ Angle

1

2 @ 15˚

2 @ 30˚

2 @ 45˚

3 @ 15˚

3 @ 30˚

3 @ 45˚

Coverage

M ax Peak

Coverage

M ax Peak

Coverage

M ax Peak

Coverage

M ax Peak

Coverage

M ax Peak

Coverage

M ax Peak

Coverage

M ax Peak

H

V

dB SPL

H

V

dB SPL

H

V

dB SPL

H

V

dB SPL

H

V

dB SPL

H

V

dB SPL

H

V

dB SPL

Vertical Rows of MTS-4As

@ Angle

1

70˚ 60˚

140

50˚

60˚

146

60˚

60˚

145

100˚

60˚

142

80˚

60˚

149

120˚

60˚

147

150˚

60˚

145

2 @ 0˚ (LT)

70˚ 30˚

146

50˚

30˚

152

60˚

30˚

151

100˚

30˚

148

80˚

30˚

155

120˚

30˚

153

150˚

30˚

151

2 @ 15˚

70˚ 50˚

145

50˚

50˚

151

60˚

50˚

150

100˚

50˚

147

80˚

50˚

154

120˚

50˚

152

150˚

50˚

150

2 @ 30˚

70˚ 90˚

143

50˚

90˚

149

60˚

90˚

148

100˚

90˚

145

80˚

90˚

152

120˚

90˚

150

150˚

90˚

148

Number of Horizontal

MTS-4As @ Angle

4 @ 15˚

4 @ 30˚

4 @ 45˚

5 @ 15˚

5 @ 30˚

5 @ 45˚

Coverage

M ax Peak

Coverage

M ax Peak

Coverage

M ax Peak

Coverage

M ax Peak

Coverage

M ax Peak

Coverage

M ax Peak

H

V

dB SPL

H

V

dB SPL

H

V

dB SPL

H

V

dB SPL

H

V

dB SPL

H

V

dB SPL

Vertical Rows of MTS-4As

@ Angle

1

100˚ 60˚

151

140˚

60˚

148

190

60˚

146

110˚

60˚

153

180˚

60˚

148

240

60˚

146

2 @ 0˚ (LT)

100˚ 30˚

157

140˚

30˚

154

190

30˚

152

110˚

30˚

159

180˚

30˚

154

240

30˚

152

2 @ 15˚

100˚ 50˚

156

140˚

50˚

153

190

50˚

151

110˚

50˚

158

180˚

50˚

153

240

50˚

151

2 @ 30˚

100˚ 90˚

154

140˚

90˚

151

190

90˚

149

110˚

90˚

156

180˚

90˚

151

240

90˚

149

11