3 explanation of functions (parameters), 1 torque boost (pr. 0 , pr. 46 ), Explanation of functions (parameters) – MITSUBISHI ELECTRIC FR-S520E User Manual

Page 77

Advertising
background image

67

Explanation of functions (parameters)

2

F

UNCT

IO

NS

2.3 Explanation of functions (parameters)

2.3.1

Torque boost (Pr. 0

, Pr. 46

)

<Setting>

•Assuming that the base frequency voltage is 100%, set the 0Hz voltage in %.

Use the RT signal to switch between two different torque boosts. (Turn on the RT
signal to make Pr. 46 valid(*).)

When using an inverter-dedicated motor (constant-torque motor), make setting as
indicated below.
(If the factory set Pr. 71 value is changed to the setting for use with a constant-torque
motor, the Pr. 0 setting changes to the corresponding value in the following table.)

Increase this value for use when the
inverter-to-motor distance is long or
motor torque is insufficient in the low
speed range (stall prevention is
activated).

Motor torque in the low-frequency
range can be adjusted to the load to
increase the starting motor torque.

Parameter

Name

Factory Setting Setting Range

Remarks

0

Torque boost

6%/5%/4%

0 to 15%

The factory setting varies according
to the inverter capacity. (Refer to the
following table for details.)

46

Second torque
boost

- - -

0 to 15%,

- - -

- - -: Function invalid. Setting is
enabled when Pr. 30 = "1".

REMARKS

* The RT signal acts as the second function selection signal and makes the other second functions valid.

Inverter Type Inverter Capacity Factory Setting

Constant-torque Motor Setting

FR-S520E
FR-S520SE
FR-S510WE

0.1K to 0.75K

6%

6% (no change)

1.5K to 3.7K

4%

FR-S540E

0.4K, 0.75K

6%

6% (no change)

1.5K

5%

4%

2.2K

3%

3.7K

4%

CAUTION

Selecting automatic torque boost control makes this parameter setting invalid.

A too large setting may cause the motor to overheat or result in an

overcurrent trip. The guideline is about 10% at the greatest.

Related parameters

• RT signal (second function "Pr. 46") setting

Pr. 60 to Pr. 63 "input terminal function selection"

(refer to page 102)

• Constant-torque motor setting

Pr. 71 "applied motor" (refer to page 73)

• Automatic torque boost control selection

Pr. 98 "automatic torque boost selection (motor

capacity)" (refer to page 125)

Pr.0
Pr.46

Setting range

0 Output frequency (Hz)

O

u

tput

vo

lt

age

Advertising
This manual is related to the following products: