Part 2: how the munchkin contender operates, Part 3: prepare munchkin contender location, Cont’d) – Munchkin Gas-Fired Hot Water Circulating Heater User Manual

Page 9: Installation manual, Gas-fired heater

Advertising
background image

8

GAS-FIRED HEATER

Installation Manual

located in the Vision One section of this
manual. Optional kit consists of the following

Outdoor sensor – 7250P-319

Indirect tank sensor – 7250P-325

Super Stor Ultra Indirect Water Heater to get a
fast recovery by prioritizing the flow at a higher
temperature than may be needed for the
central heating circuits (this will require two
separate circulators). You must follow the
piping, wiring and programming instructions

PART 2: HOW THE MUNCHKIN CONTENDER OPERATES

(CONT’D)

F

D

E

C

P

M

S

K

H

L

1

2

3

B

A

BACK VIEW

FRONT VIEW

RIGHT SIDE

VIEW

VIEW

LEFT SIDE

7

Q

N

O

R

8

G

J

EXHAUST VENT CONNECTION

SYSTEM RETURN

4

CONDENSATE CUP/DRAIN ASSEMBLY

5

7

8

SYSTEM RELIEF

GAS LINE CONNECTION

6

COMBUSTION AIR INLET CONNECTION

SYSTEM SUPPLY

1

2

3

ELECTRICAL BOX/CONTROL PANEL

MUNCHKIN CONTENDER HEATER DIMENSIONS AND SPECIFICATIONS

MODEL

NUMBER

BTU/HR

INPUT

LOW

FIRE

BUT/HR

INPUT

HIGH

FIRE

A

B

C

D

E

F

G

H

J

K

L

M

N

O

P

Q

R

S

COMBUSTION AIR

INLET/EXHAUST

VENT

CONNECTION

SIZE

SYSTEM

RELIEF

PIPE SIZE

SYSTEM SUPPLY/

SYSTEM RETURN/

PIPE SIZE

GAS

LINE

CONN.

HEATER
WATER

VOLUME

ENERGY
FACTOR

EF

3

DOE

EFF.

AFUE

1

LOW

WATER

EFF.

LTAAE

2

APPROX.

SHIPPING

WEIGHT

MC50

18,000

50,000

12.50

27.50

7.00

2.75

5.25

9.00

17.25

7.75

5.50

2.75

5.25

5.00

9.00

2.75

4.00

6.50

10.25

4.00

2.00

.75

1.25

.75

.58

.91

92%

98%

71 LBS

MC80

19,000

80,000

12.50

27.50

7.00

2.75

5.25

9.00

17.25

7.75

5.50

2.75

5.25

5.00

9.00

2.75

5.25

6.50

10.25

4.00

2.00

.75

1.25

.75

.67

.93

92%

98%

74 LBS

MC99

44,000

99,000

13.50

27.50

7.00

2.75

6.50

10.25

17.25

7.75

5.50

2.75

5.25

6.00

9.00

2.75

7.75

6.50

11.25

4.00

2.00

.75

1.25

.75

.96

.95

93%

98%

84 LBS

MC120

44,000 120,000 13.50

27.50

7.00

2.75

6.50

10.25

17.25

7.75

5.50

2.75

5.25

6.00

9.00

2.75

7.75

6.50

11.25

4.00

2.00

.75

1.25

.75

.96

.95

92%

98%

84 LBS

1.

Tested by Heat Transfer Products to the ANSI/ASHRAE 103

2.

Tested by Heat Transfer Products to the ANSI/ASHRAE Standard 103 with 90° return and 110° supply water

3.

Tested by Heat Transfer Products to the 10 CFR 430.23 2005

PART 3: PREPARE MUNCHKIN CONTENDER LOCATION

A. INSTALLATIONS MUST COMPLY WITH:

Local, state, provincial, and national codes,
laws, regulations and ordinances.

National Fuel Gas Code, ANSI Z223.1 – latest
edition.

National Electrical Code.

For Canada only: B149.1 or B149.2
Installation Code, CSA C22.1 Canadian
Electrical Code Part 1 and any local codes.

Advertising