MTD -ERV 350 User Manual

Page 15

Advertising
background image

Menu P1 ! Status of the functions

Ventilation functions

Sub-menu Description

Activated / not activated

P10

Menu 20 currently active?

Yes (1) / No (0)

P11

Menu 21 currently active?

Yes (1) / No (0)

P12

Menu 22 currently active?

Yes (1) / No (0)

P13

Menu 23 currently active?

Yes (1) / No (0)

P14

[Not available]

[Not available]

P15

Menu 25 currently active?

Yes (1) / No (0)

P16

Menu 26 currently active?

Yes (1) / No (0)

P17

Menu 27 currently active?

Yes (1) / No (0)

P18

Menu 28 currently active?

Yes (1) / No (0)

P19

Menu 29 currently active?

Yes (1) / No (0)

2

Instructions for the User 11

Menu P2 ! Set time delays

Time delay values

m

u

m

i

n

i

M

n

o

i

t

p

i

r

c

s

e

D

u

n

e

m

-

b

u

S

Maximum Default

setting

P20

(Option)*

Deactivation delay for extractor hood
function.
• 'x' minutes after pressing the extrac-

tor hood switch, the MTD-ERV 350
returns to the previously set level.

0 Min.

180 Min.

30 Min.

P21

(Option)*

Note:
Only for systems with wired
switch and only if your system is
equipped with a second position
switch in the bathroom.

Activation delay for the bathroom
switch (to switch to the HIGHEST LEVEL).
• 'x' minutes after turning on the

bathroom switch, the MTD-ERV 350
switches to the HIGHEST LEVEL.

0 Min.

15 Min.

0 Min.

P22

(Option)*

Note:
Only for systems with wired
switch and only if
your system is equipped with
a second position switch in the
bathroom.

Deactivation delay for the
bathroom switch (to switch to the NOR-
MAL LEVEL).
• 'x' minutes after turning on the bath-

room switch, the MTD-ERV 350 re-
turns to the NORMAL LEVEL.

0 Min.

120 Min.

30 Min.

P23

Note:
Only for systems with a wired
position switch.

Deactivation delay
for ventilation position 3.
• When position 3 (HIGHEST LEVEL) is

switched on briefl y (< 3 seconds), the
MTD-ERV 350 remains at this position
for the time set in this menu.

If, within the run-down time, the posi-
tion switch or the radio remote control
is activated, the MTD-ERV 350 switches
immediately to the set ventilation level.

0 Min.

120 Min.

30 Min.

P24

Filter warning
• Here the user can select when "FILTER

DIRTY" is to appear on the CC Ease
display.

1 week

26 weeks 16 weeks