11

Horizontal Venting with One (1) Elbow:

Figure 9: Horizontal Venting with One (1) Elbow

Vertical Venting with Two (2) Elbows:

Figure 10: Vertical Venting with Two (2) Elbows

V, Vertical

H, Horizontal

Elbow (5 inches)

30 inches Max

Elbow (5 inches)

30 inches Corner Max

1 foot Min

5 feet Max

2 feet Min

10 feet Max

3 feet Min

15 feet Max

4 feet Min

20 feet Max

NOTE

If a 90

°° Elbow is first attached to the unit, the

maximum horizontal run, H, is 30 inches

straight out, and 30 inches at a corner

installation.

V, Vertical

H, Horizontal

1 foot Min

5 feet Max

2 feet Min

10 feet Max

3 feet Min

15 feet Max

4 feet Min

20 feet Max

NOTE

V1 dimension must satisfy this condition:

V + H + V1

<< 40 feet.