Meyer Sound 80 User Manual

Page 36

Advertising
background image

APPENDIX A: ACHERON 80 AND ACHERON 100 SPECIFICATIONS

36

Nominal Input Sensitivity

10 dBV (3.2 V rms, 4.5 V peak) continuous is typically the onset of limiting for noise and music

Input Level

Audio source must be capable of producing +20 dBV (10 V rms, 14 V peak) into 600

Ω to pro-

duce the maximum peak SPL over the operating bandwidth of the loudspeaker

AMPLIFIER

Type

Complementary MOSFET output stages (class AB/H)

Output Power

1685 W total (1125 W low channel, 560 W high channel)
Note: Amplifier wattage rating based on the maximum unclipped burst sine-wave RMS volt-
age the amplifier will produce into the nominal load impedance: low frequency channel, 67 V
rms (95 V peak) into 4 ohms; high frequency channel, 67 V rms (95 V peak) into 8 ohms.

Total Output

3370 W peak

THD, IM TIM

<.02%

Load Capacity

4

Ω low channel, 8 Ω high channel

Cooling

Forced air cooling, two internal fans (one ultra low-speed fan, one reserve fan)

AC POWER

Connectors

250 V NEMA L6-20 (twistlock) inlet or IEC 309 male inlet

Voltage Selection

Automatic, two ranges, each with high-low voltage tap (uninterrupted)

Safety Agency Rated Operating
Voltage

95–125 V AC; 208–235 V AC; 50/60 Hz

Turn On/Turn Off Points

85–134 V AC; 165–264 V AC

Current Draw

Idle Current

0.71 A rms (115 V AC); 0.38 A rms (230 V AC); 0.79 A rms (100 V AC)

Maximum Long-Term Continu-
ous Current

5.8 A rms (115 V AC); 2.8 A rms (230 V AC); 6.3 A rms (100 V AC)

Burst Current

6.4 A rms (115 V AC); 3.2 A rms (230 V AC); 7.2 A rms (100 V AC)
Note: AC power cabling must be of sufficient gauge so that under burst current rms condi-
tions, cable transmission losses do not drop below the loudspeaker’s specified operating volt-
age range.

Ultimate Short-Term Peak Cur-
rent

26 A peak (115 V AC); 14 A peak (230 V AC); 28 A peak (100 V AC)

Inrush Current

7 A peak (115 V AC); 7 A peak (230 V AC); 10 A peak (100 V AC)

PHYSICAL

Enclosure

Premium birch plywood

Finish

Low gloss, black textured

Mounting

3/8” threaded points on side corners for optional bracket adapters, which allow the Acheron
to be mounted to floors with uptilt or downtilt, as well as on top of the Acheron LF (also with
uptilt or downtilt)

Dimensions

31.00" w x 35.00" h x 20.50" d (787 mm x 889 mm x 521 mm)

Weight

Weight 173 lbs (78.47 kg)

ENVIRONMENTAL

Operating Temperature

0° C to +45° C

Non Operating Temperature

<–40° C or >+75° C

Humidity

to 95% at 35° C

Operating Altitude

to 4600 m (15,000 ft)

Non Operating Altitude

to 95% at 35° C

Acheron 80 and Acheron 100 Specifications