Manitowoc Ice K00157 User Manual

Manitowoc Ice Freezers

Advertising
background image

K00156/157

ADAPTER

KIT

Installation Instructions

1. Use the K00156 to install a Q-0200, Q-0450, Q-0600, Q-0800, Q-1000, and 30" S-series ice machines on a

Manitowoc C-950 bin.
Use the K00157 to install a Q-0200, Q-0450, Q-0600, Q-0800, Q-1000, and 30" S-series ice machines on a
Manitowoc C-970 bin.

2. Installation (the bin must be level before starting):

A. Remove the existing foam tape and ice deflector from bin.
B. For the K00156 kit, slide the support brackets onto the deflectors in the kit. For the K00157 kit, use the deflector

from the bin. Locate, as shown on the drawing below. Secure the deflector(s) to the bin with the screws removed
earlier.

C. Apply approximately 10 1/2” (26.7 cm.) of foam tape to the bottom front edge of the adapters between the bin and

the adapters.

D. Place the adapters on the bin, as shown.
E. Using the adapters as templates, drill four 5/32” (4 mm.) holes, .500” (12.7 mm.) deep maximum, in bin.

Warning: Do not drill through interior liner. Attach with the screws provided.

F. Apply foam tape to the edge of the adapters, as shown, and on the front and rear of the bin between the adapters.

Note: We recommend using RTV at intersections and along front inside edge of foam tape to prevent water
tracking. Use double tape thickness with S-series ice machines.

3. Refer to ice machine installation manual for ice machine installation procedures.


























Manitowoc Ice, Inc.

2110 South 26

th

Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA

Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879 8011633
Web Site - www.manitowocice.com Rev. 05/12/04

Q-Model Ice

Machine Back

LH Adapter

Screws from Kit

(TYP)

RH Adapter

12 1/2”

6 3/16”

6 3/4”

Double Thickness of
Tape with 30" S-series
Ice Machines