Master Appliance Heat Blower User Manual

Page 2

Advertising
background image

The Masterflow

®

Heat Blower

is a heavy-duty, industrial-
quality heat blower suitable for
continuous duty applications.
It produces a high volume of
hot air for demanding indus-
trial applications. The
adjustable stand features a
keyhole slot for easy equip-
ment mounting and allows the
nozzle capability of rotating
90° (horizontal to vertical).

Your Masterflow

®

is equipped

with a thermal fuse which will
protect the element from over-
heating or burn out due to
a nozzle blockage or motor
failure.

Heat blowers are a source
of extremely high tempera-
ture flameless heat (up to
750°/400°C). As with other
products which generate

extremely high tempera-
tures, regardless of your
specific application,
extreme care and caution
should be observed when
using this product.
Therefore, we recommend
that you pay particular
attention to the safety
instructions which we have
provided for your protection.

WARNING: THIS PRODUCT
IS A SOURCE OF VERY
HIGH TEMPERATURE
FLAMELESS HEAT. AS
WITH ANY ELECTRICAL
TOOL, WHEN USING HEAT
TOOLS, ALWAYS FOLLOW
BASIC SAFETY PRECAU-
TIONS, INCLUDING THE
FOLLOWING, TO REDUCE
THE RISK OF FIRE, ELEC-
TRIC SHOCK OR PER-
SONAL INJURY.

1) Read and understand this

instruction manual before
using. Save this manual for
future reference.

WARNING: To reduce the
risk of fire or electric shock,

do not expose heat blow-
ers to rain or moisture.
Store indoors. Connect to
grounded outlet only.

2) Do not use plug adaptors or

remove the ground prong
from the plug. This tool is
equipped with a 3-prong
plug and a 3-wire grounding
system. Connect to prop-
erly grounded outlets only.

3) Use heat blower only on

adequately rated circuits to
avoid overheating of
electrical systems.

4) Masterflow Heat Blowers

can produce up to
750°F/400°C of flameless

2

Description & Introduction

Important Safety Instructions

Specifications

heat out of the nozzle. Do
not direct this hot air stream
at your clothing, hands or
body parts. Do not use as a
hair dryer.

5) Do not touch nozzle open-

ing or nozzle shield until
cool. When in “Hot” mode,
extreme heat is generated
at those areas. Always hold
tool by the handle or use
permanently attached
stand.

6) Run on “Cold” before turn-

ing off. The nozzle and
shield require approxi-
mately 3 minutes to
become cool to the touch.

*Temperature

Model

°F

°C

Volts

Amps

AH-301

300

50

120

10.0

AH-302

300

150

220/240

5.2

AH-501

500

260

120

14.0

AH-502

500

260

220/240

7.3

AH-751

750

400

120

18.0

AH-752

750

400

220/240

9.4

*Average temperature measures 1" from nozzle.