Marquis 38

17

FAN & VALVE WIRING DIAGRAM/INSTRUCTIONS

ELECTRICAL CONNECTIONS (for optional convection fan kit FK 36/38 only)

Install the fan first. Remove the lower louvers and gently place the bottom front lip of the blower
mounting bracket into the opening. Slide the blower assembly into the bottom of the fireplace.
Rotate the blower into position. Be careful not to damage the fan blades. The fan blades will now
face towards you. Line up the holes on fan bracket to the mounting bracket at the bottom of the
fireplace. Place a screw at each of the three holes and tighten.

Run 120VAC power line through the left side of the fireplace and into the bottom of the gas
fireplace.

Be sure to connect a grounding wire to the side of gas fireplace. Use any screw hole on the side
for this purpose.

Slide the thermal snap switch into the fork like bracket underneath the left side of the firebox.

Neatly tie down and tuck the wires down at the bottom and to the back of the fireplace.

CAUTION: Do not allow any wires to touch the bottom of the firebox. Otherwise, the wires will
melt and short-out.

Screw the speed controller bracket to the bottom left sidewall of the gas fireplace.

VALVE CONNECTIONS

SPEED CONTROL

LINE

CONVECTION FAN

GROUND

110F (43ºC) N.O.
THERMAL SNAP SWITCH

NEUTRAL

TO

APPLIANCE

120 VAC

WIRING DIAGRAM

OPTIONAL

REMOTE SWITCH

OPTIONAL

THERMOSTAT

SWITCH

TO SPARKER

PILOT

ASSEMBLY

THERMOPILE

SPARK ELECTRODE

THERMOCOUPLE

PILOT

BURNER

300F N.C.

SPILLAGE

SWITCH


Advertising