Countertop cut-out 8, Countertop cut-out – Miele KM 406 User Manual

Page 8

Advertising
background image

All Miele combisets have the same
length and width. Make sure that there
is enough room under the countertop to
allow for the depth of the various
appliances. Remember to allow
clearance for the gas regulator and gas
pipe that must be connected to the
appliance.

^ Rember to maintain the minimum

safety distances to combustible
surfaces:

– 2

3

/

4

" (70 mm) between the cut-out

and the back wall, and
– 12 " (305 mm) between the cut-out
and a side wall or tall unit to the right
or left of the cut-out.

^ See "IMPORTANT SAFETY

INSTRUCTIONS" for further
installation information.

Installing one or multiple appliances:

Cut out the countertop using the
dimensions listed in the following table.

Number of
cooktops

Cut out width

Dimension "B"

1

10

13

/

16

"

(275 mm)

2

22

1

/

8

"

(562 mm)

3

33

1

/

2

"

(851 mm)

4

44

13

/

16

"

(1138 mm)

5

56

1

/

8

"

(1426 mm)

6

67

1

/

2

"

(1714 mm)

7

78

13

/

16

"

(2002 mm)

The tolerance for each dimension is

1

/

16

" (1 mm).

When installing more than one
combiset, a support bar must be
installed between the appliances.
Install the support bars as shown in
the relevant section before setting
the appliances into the countertop.

Countertop cut-out

8

Advertising