M•800 SPECIFICATIONS

Maximum Power:

175 watts per channel into 8 ohms
275 watts per channel into 4 ohms
400 watts per channel into 2 ohms
550 watts into 8 ohms bridged
800 watts into 4 ohms bridged

Note: Power ratings are specified at 120VAC line voltages.

The M•800 power amplifier draws large amounts of cur-
rent from the AC line with continuous sine wave testing.
Accurate measurement of power requires a steady and
stable AC supply. This means the line impedance must
be very low to insure that the peak AC line voltage does
not sag to less than 97% of its value.

If driving highly reactive loads, we recommend that the
limiter circuit be engaged.

Continuous Sine Wave Average Output Power,
both channels driven:

150 watts per channel into 8 ohms from 40Hz to 20kHz,
with no more than 0.025 % THD

225 watts per channel into 4 ohms from 40Hz to 20kHz,
with no more than 0.05 % THD

280 watts per channel into 2 ohms from 40Hz to 20kHz,
with no more than 0.1 % THD

Bridged mono operation:

450 watts into 8 ohms from 40Hz to 20kHz, with no more
than 0.05 % THD

560 watts into 4 ohms from 40Hz to 20kHz, with no more
than 0.1 THD

Power Bandwidth:

20Hz to 70kHz (+0, –3 dB)

Frequency Response:

20Hz to 40kHz (+0, –1 dB)
10Hz to 70kHz (+0, –3 dB)

Distortion:

THD, SMPTE IMD, TIM (at rated power)

< 0.025% @ 8

< 0.05% @ 4

< 0.1% @ 2

Signal-to-Noise Ratio:

> 104 dB below rated power into 4 ohms

Channel Separation:

> 70 dB @ 1kHz

Damping Factor:

> 250 from 10 to 400Hz

Input Impedance:

20k

balanced

Input Sensitivity:

1.23 volts (+4 dBu) for rated power into 4 ohms

Voltage Gain:

28.0 dB

Maximum Input Level:

9.75 volts (+22 dBu)

Rise Time:

< 5

µ

s

Slew Rate:

Voltage Slew Rate

> 40V/

µ

s

> 80V/

µ

s bridged

Current Slew Rate

> 20A/

µ

s at 2

CMRR:

> 40 dB, 20Hz to 20kHz

Load Angle:

8(

±

jx) time independent at 8

4(

±

jx) time dependent, T > 6 min. at 4

2(1

±

jx) time dependent, T > 2 min. at 2

Transient Recovery:

< 1

µ

s for 20 dB overdrive @ 1kHz

High Frequency Overload and Latching:

No latch up at any frequency or level.

High Frequency Stability:

Unconditionally stable driving any reactive or capacitive
load.

Turn On Delay:

3-4 seconds

Variable Low-Cut Filter:

10Hz (Off) to 170Hz, 2nd Order Bessel

Constant Directivity High Frequency Boost:

2kHz to 5.5kHz (+3 dB points)
6 dB/octave high-frequency shelving filter,
(shelving occurs at approximately 30kHz)