Installing the Coaxial Cables

Connections to the housing are made using standard KS-type housing port entry connectors.
Pin-type connectors with a nominal center conductor diameter of 0.067 inches are required. The
following table provides the center conductor pin length for the various amplifiers:

Amplifier models

Pin length (inches)

BLE*/*, MB*/*,
BT*/*, MBE*/*

1.50 minimum to 1.65 maximum

Pin

length

Use a torque wrench or Phillips screwdriver to tighten the center conductor seizure screw to a
torque of 12 in-lbs.

Powering the Amplifier

For optimal operation, verify that the ac input from the feederline to the power supply is
between 38 and 90 Vac (rms) with a line frequency of 50 or 60 Hz. The waveshape of the input
voltage must be quasi-squarewave.

The power supply provides the additional feature of a two position (

LO

and

HI

) selector that sets

the startup voltage of the power supply. The startup voltage is 38 Vac for the

LO

position and

55 Vac for the

HI

position. All units are shipped with the selector set in the

LO

position. The

LO

position is used with 60 Vac systems where 38 Vac startup voltage is required. For systems
operating at 90 Vac, the selector can be in the

LO

or

HI

position. Note that changing the selector

does not change the upper voltage limit but affects only the startup voltage. The voltage selector
should be switched only if the power supply approaches its maximum load rating.

There is no damage to the amplifier if the jumper is not changed. However, changing the jumper
ensures that the dc supply does not turn on until the proper input voltage level is reached —
either 38 Vac or 55 Vac. This prevents excessive loading of the system power supply during
turn-on after a system shutdown.

DANGER!

Voltages up to 90 Vac are accessible. To avoid a shock hazard, confirm that the STARLINE amplifier is not powered
before removing the cover or replacing the fuses.

To power the amplifier:

1

Set the power supply jumper for 90 Vac operation if required by your system.

2

Determine which fuses should be installed to route power to the appropriate ports.

3

Verify that the power supply output voltage is

+24 Vdc.