Digital Temperature Controller

PN 36056

Service instructions

Push the lock key and the service key together to reach SP LOK,
then use the service key to step through the other functions listed
below.

Use the arrow keys to change the function settings.

Factory settings are as shown below.

This function will record the
highest ambient temperature of
the temperature controller;
68ºF/20ºC is the original
reading.

F = degrees Fahrenheit
C = degrees Celsius

SET = set point display
ACT = actual temperature
display.

LOCK

KEY

SERVICE

KEY

+

NO = set point
unlocked
YES = set point
locked

no

d Eg F

5 E

68

Push the lock key and the display key to
enable the programming function of the
“OnOF or “Pid” temperature control
system.

This display allows programming the controller for either the
standard O N / O F F mode or the PID (360EWB models) mode for
the modulating gas control system.

or

O n O F

P d

+

LOCK

KEY

DISPLAY

KEY

OnOF = standard on/off temperature cycling system (gas & electric)
PiD = modulating temperature proportioning system
(gas 360 EWB only)

1)

2)

OVER TEMP

SET PT

SP LOCK

SP LOCK

HEAT ON

ACTUAL
TEMP

SET PT

HEAT ON

ACTUAL
TEMP

OVER TEMP

SP LOCK

OVER TEMP

SP LOCK
OVER TEMP

F

SET PT

HEAT ON

ACTUAL
TEMP

b

0

SET PT

HEAT ON

ACTUAL
TEMP

OVER TEMP

SP LOCK

SET PT

HEAT ON

ACTUAL
TEMP

E

y

L

S

Confirms that the Pid
(Modulating) setting
has been locked in if
the Pid setting was
chosen.

If the “On/Of” setting is chosen, the
“LyES” display will be bypassed.

This display is the BIAS (actual
temperature) adjustment scale
which is Factory set at zero.
The Factory must be consulted
for any adjustments to the
BIAS.

Indicator flashing

Indicator not flashing

9

Figure 14 - Service Instructions