Electrical service, Voltage, Fuse/circuit breaker – Manitowoc Ice UNDERCOUNTER QM30 User Manual

Page 11: Electrical rating

Advertising
background image

Section 2

Installation Instructions

Part Number 000001772 07/08

2-3

Electrical Service

VOLTAGE

The maximum allowable voltage variation is

± 10% of

the rated voltage on the ice machine model/serial
number plate at start-up (when the electrical load is
highest).

FUSE/CIRCUIT BREAKER

A separate fuse/circuit breaker must be provided for
each ice machine.

NOTE: A disconnect means must be provided for field
wiring.

ELECTRICAL RATING

The electrical rating is used to help select the wire size
of the electrical supply. The wire size (or gauge) also
depends on location, materials used, length of run, etc.,
so it must be determined by a qualified electrician.

!

Warning

All wiring must conform to local, state and national
codes.

Voltage Phase

Electrical Rating

230/50/1

0.6kW

115/60/1

0.6kW

!

Warning

The ice machine must be grounded in accordance
with national and local electrical codes.

!

Warning

Never use an extension cord. If an outlet is not
within reach of the ice machine’s power cord, have
a proper amperage outlet wired closer to the ice
machine.