Installing/Removing

Getting things ready to install your
appliance (continued)

CORRECT LEVELING OF UNIT IS ESSENTIAL

It is important for the machine to be perfectly level.

The angle of inclination on the work surface must not

be more than 2 degrees. For this reason the machine

is fitted with adjustable feet used for leveling the

machine before use. In the case of carpeted flooring,

remember to check that the ventilation in the support

area is not plugged.

• Check that all ducting is lint free. Secure ducting with clamps or metal

tape.

• The exhaust duct must end with an approved exhaust vent hood with

swing out dampers or appropriate louvers.

• Flex or rigid metalic ducting is recommended.

• Exhaust duct should be short and straight and slope downwards and

away from the appliance. Long exhaust duct runs can increase drying

time and collect lint.

IMPORTANT! THE EXHAUST DUCT SHOULD NOT BE INSERTED INTO A

CHIMNEY WALL, CEILING OR CONCEALED SPACE OF STRUCTURE.

Exhaust Duct Installation