1-7-1

T2202EA

ELECTRICAL ADJUSTMENT INSTRUCTIONS

General Note: “CBA” is abbreviation for
“Circuit Board Assembly.”

Note: Electrical adjustments are required after

replacing circuit components and certain
mechanical parts. It is important to perform
these adjustments only after all repairs and
replacements have been completed.
Also, do not attempt these adjustments unless
the proper equipment is available.

Test Equipment Required

1. NTSC Pattern Generator (Color Bar W/White

Window, Red Color, Dot Pattern, Gray Scale,
Monoscope, Multi-Burst)

2. AC Milli Voltmeter (RMS)

3. Alignment Tape (FL8A, FL8N), Blank Tape

4. DC Voltmeter

5. Oscilloscope: Dual-trace with 10:1 probe,

V-Range: 0.001~50 V/Div,
F-Range: DC~AC-60 MHz

6. Frequency Counter

7. Plastic Tip Driver

8. Color Analyzer

How to make service remote control
unit:

1. Prepare normal remote control unit (Part No.

NE204UD or NE209UD). Remove 4 screws from
the back lid (Fig. 1).

2. Cut off pin 10 of the remote control

microprocessor and short circuit pins 10 and 17 of
the microprocessor with a jumper wire

How to enter the Service mode:

Service mode:

1. Use the service remote control unit.

2. Turn the power on. (Use main power on the TV

unit.)

3. To enter the TV mode, press [CH. o / p] buttons

on the TV unit.

4. Press [DISC MENU] button on the service remote

control unit. Version of micro computer will display
on the CRT. (Ex: BA4-0.16)

X-Ray Protection Test

X-Ray protection test should be done when replacing
any parts of this chassis.

1. Short both ends of R2592 (on Sub CBA).

2. Confirm that the main power turns off.

3. If the main power does not turn off, then replace

the following parts (D2591, Q2591, R2592,
R2593, R2594 and IC1201).

4. Perform steps 1 to 3 again.

1. DC 120V (+B) Adjustment

Purpose: To obtain correct operation.

Symptom of Misadjustment: The picture is dark and
unit does not operate correctly.

Note: TP2501(+B), TP2504(GND) --- Sub CBA,

VR1601 --- Main CBA

1. Connect the unit to AC Power Outlet.

2. Connect DC Volt Meter to TP2501(+B) and

TP2504(GND).

3. Adjust VR1601 so that the voltage of TP2501(+B)

becomes +120

±1.0 V DC.

Fig. 1

Screws

Remote control unit (bottom)

Test Point

Adj. Point

Mode

Input

TP2501(+B)

TP2504(GND)

VR1601

---

---

Tape

M. EQ.

Spec.

---

DC Voltmeter

+120

±1.0 V DC