Maintenance – Murray 405000x8C User Manual

Page 20

Advertising
background image

MAINTENANCE

20

F-040735L

MAINTENANCE CHART

PROCEDURE

EACH

USE

FIRST

2

HOURS

EVERY

25

HOURS

EVERY

50

HOURS

EVERY

100

HOURS

BEFORE

STORAGE

Blade, Inspect and Sharpen

Blade Rotation Control, Check

M

Brake, Check

M
O
W

Clutch, Check

W

E

Tires, Check

E

R

Battery, Check and Charge

Battery, Clean

Lubrication *

*

Dusty conditions every 25 hours.

GENERAL RECOMMENDATIONS

1.

The owner’s responsibility is to maintain this product. This will
extend the life of the product and is also necessary to maintain
warranty coverage.

2.

Check the spark plug, drive brake, lubricate the unit, and clean
the air filter once a year.

3.

Check the fasteners. Make sure all fasteners are tight.

4.

Follow the Maintenance section to keep the unit in good operat-
ing condition.

WARNING: Before you make an inspection, adjust-
ment, or repair to the unit, disconnect the wire to the
spark plug. Remove the wire from the spark plug to
prevent the engine from starting by accident.

NOTE: Torque is measured in foot pounds (metric Nm). This
measurement describes how tight a nut or bolt must be. The
torque is measured with a torque wrench.

HOW TO CHECK THE MUFFLER

Check the muffler every 50 hours. Make sure the muffler is correctly
mounted and is not loose. If the muffler is worn or burnt, replace with
a new muffler. A worn muffler is a fire hazard and can also damage
the engine.

If you mount a spark arrester to the muffler, also check the spark
arrester when you check the muffler. If the spark arrester is worn or
damaged, replace it with a new spark arrester. See your nearest
authorized service center for a spark arrester.