McIntosh C2300 User Manual

Page 4

Advertising
background image

4

XLR Connectors

Below is the Pin configuration for the XLR Balanced Input

and Output Connectors on the C2300. Refer to the dia-

grams for connections:

PIN 1: Shield/Ground

PIN 2: + Output

PIN 3: - Output

Power Control and Trigger Connectors

The C2300 Power Control and

Trigger Output Jacks send Power

On/Off Signals when connected to

McIntosh and other Components. An

additional connection on the Main

Power Control Jack is for controlling

the illumination of the Power Output

Meters on McIntosh Power Ampli-

fiers. A 1/8 inch stereo mini phone

plug is used for connection to the

Power Control and Trigger Outputs

on the C2300.

Note: The Data, Power Control and

Trigger Connecting Cable is

available from the McIntosh

Parts Department:

Data, Power Control and Trig-

ger Cable Part No. 170-202

Six foot, shielded 2 conductor,

with 1/8 inch stereo mini phone plugs on each end.

Data Port Connectors

The C2300 Data Out Ports send Remote Control Signals to

McIntosh Source Components. A 1/8

inch stereo mini phone plug is used for

connection.

General, Connector and Cable Information

Connector and Cable Information

Data

Signal

N/C

Data

Ground

PIN 2

PIN 1

PIN 3

PIN 1

PIN 2

PIN 3

Trigger

Control

Ground

N/C

1. The C2300 uses Vacuum Tubes for amplifying the

audio signal. The C2300 is designed to have only quali-

fied Service Personnel perform any part(s) replacement

including all the vacuum tubes.

2. For additional connection information, refer to the

owner’s manual(s) for any component(s) connected to

the C2300 Tube Preamplifier.

3. The Main AC Power going to the C2300 and any other

McIntosh Component(s) should not be applied until all

the system components are connected together. Failure

to do so could result in malfunctioning of some or all of

the system’s normal operations. When the C2300 and

other McIntosh Components are in their Standby Power

Off Mode, the Microprocessor’s Circuitry inside each

component is active and communication is occurring

between them.

4. Up to two Sensors can be wired in parallel for Remote

Control of the C2300 from other rooms.

5. Balanced and Unbalanced Inputs and Outputs can be

mixed. For example, you may connect signal sources to

Unbalanced Inputs and send signals from the Balanced

Outputs. You can also use Balanced and Unbalanced

Outputs simultaneously, connected to different Power

Amplifiers.

General Information

Power

Control

Meter

Illumination

Control Ground

Main Output Jack

Power

Control

Ground

N/C

Output 1 and 2, ACC

Jacks

Advertising