Maytag HVP41240PCGA User Manual

Page 13

Advertising
background image

13

The water within the water heater tank expands as it is heated and
increases the pressure of the water system. If the relieving point of the
water heater’s temperature-pressure relief valve is reached, the valve
will relieve the excess pressure. The temperature-pressure relief
valve is not intended for the constant relief of thermal
expansion.
This is an unacceptable condition and must be corrected.

It is recommended that any devices installed which could create a closed
system have a by-pass and/or the system have an expansion tank to
relieve the pressure built by thermal expansion in the water system.
Consult Maytag Customer Service at 1-800-788-8899 for an
authorized installer on how to control this situation
.

NOTE: To protect against untimely corrosion of hot and cold
water fittings, it is strongly recommended that di-electric unions
or couplings be installed on this water heater when connected
to copper pipe.

FIGURE 16.

WATER PIPING

HOTTER WATER CAN SCALD:
Water heaters are intended to produce hot water. Water heated to a
temperature which will satisfy space heating, clothes washing, dish
washing, cleaning and other sanitizing needs can scald and permanently
injure you upon contact. Some people are more likely to be permanently
injured by hot water than others. These include the elderly, children, the
infirm, or physically/mentally handicapped. If anyone using hot water in
your home fits into one of these groups or if there is a local code or
province law requiring a certain temperature water at the hot water tap,
then you must take special precautions. In addition to using the lowest
possible temperature setting that satisfies your hot water needs, a
means such as a *mixing valve, shall be used at the hot water taps used
by these people or at the water heater, see Figure 2. Valves for reducing
point of use temperature by mixing cold and hot water are also available:

Consult Maytag Customer Service (1-800-788-8899). Follow
manufacturer’s instructions for installation of the valves. Before changing
the factory setting on the thermostat, read the “Temperature Regulation”
section in this manual.

This water heater shall not be connected to any heating system or
component or used as a non-potable water heating appliance.

All piping components connected to this unit shall be suitable for use
with potable water.

Toxic chemicals, such as those used for boiler treatment shall not be
introduced into this system.

When the system requires water at temperatures higher than required
for domestic water purposes, a tempering valve must be installed. Please
refer to Figure 2 for suggested piping arrangement.

Water supply systems may, because of such events as high line
pressure, frequent cut-offs, the effects of water hammer among others,
have installed devices such as pressure reducing valves, check valves,
back flow preventers, etc. to control these types of problems. When
these devices are not equipped with an internal by-pass, and no other
measures are taken, the devices cause the water system to be closed.
As water is heated, it expands (thermal expansion) and closed systems
do not allow for the expansion of heated water.

Advertising
This manual is related to the following products: