13
Security Password Default for IMC Connections
If the USN is connected to an IMC controller with the CRT Security feature enabled, the USN
will allow iMonitor software to configure security parameters. In order to configure security
parameters, a user must log into the controller using a password. This password is stored on
the USN board.
The default password is “manager”.
If it is lost, the password can be reset back to default:
1. Disconnect the serial communication cable from the USN.
2. Change the Device type setting from Swing Panel to a non-swing panel type (e.g. PCA
Simplex A2K) and save.
3. Reset board by pressing the RSTA button.
4. Change Device type back to Swing Panel and save.
5. Remove power from USN.
6. Reconnect serial communication cable.
7. Reconnect power to USN.
KCE Functionality
In order to utilize car recall functionality with iMonitor software, the KCE (Keyboard Control
for Elevators) feature must be enabled on the controller.
On PCA-type controllers, activate KCE from the Extra Features menu. Please consult the
appropriate controller documentation for details.
On IMC-type controllers, the KCE feature must be pre-programmed on the controller software.
You can verify the presence of the KCE feature by connecting to the group controller using a
CRT, terminal emulator or TigerTerm software. Go to the Job Configuration screen (F6) and
view the Other Options menu item. Please consult the appropriate controller documentation
for more details.
Note
KCE functionality is available on only certain MCE controllers. Check the controller user man-
ual.