The movement of the vapour canopy
can be adjusted. This may be
necessary, for instance, if a heavy
cabinet panel is mounted. In the front of
the lower edge of the unit, two
openings (right and left) give access to
two adjustment screws.

^ Remove both cover caps.
^ Using a Philips screwdriver, adjust

both sides evenly:
- clockwise: the folding mechanism
becomes stiffer.
- counterclockwise: the folding
mechanism becomes freer.

^ Replace the cover caps.

Height adjustment

^ Using the screws of the adjustable

brackets, you can align the unit with
the height of the adjoining cabinets.
Turn them
– counterclockwise: The unit is
raised.
– clockwise: the unit is lowered.

^ If necessary, adjust the depth again.

^ Fix the hood to the wall using the

5.2 x 50 mm screws provided.