Warn ing, Vent requirements – Monessen Hearth ILDV20PV User Manual

Page 13

Advertising
background image

83D0511

ILDV20/ILDV30 Fireplace Insert

13

VeNt iNStALLAtiON

W

ARN

iNG

•

Make sure the exhaust pipe on heater connects to exhaust
portion of cap. Attach flex liners.
Figure 6

•

Do not crimp or rupture liner when bending it into chimney
offsets.

VeNt RequiReMeNtS

•

The exhaust vent must reline the entire length of chimney and terminate above chimney top.

•

Vent must meet all vent manufacturer's requirements when installed.

•

Make sure you have the following before installing unit:

•

3" and 3" UL 1777 Listed gas liner for air inlet and exhaust.

•

Vertical termination kit (AI31TK33A, HEDV3T81, HEDV3T11, HEDVRT)

FP1922
vent requirements
9/08

Maximum Height 40'

(1.9 m)

Minimum Height 10'

(3 m)

Exhaust

Inlet

Figure 6
Venting Unit

FP19