Series ps540 electrical specifications – Middleby Marshall PS540 User Manual

Page 6

Advertising
background image

2

SECTION 1
DESCRIPTION

PS540 SERIES OVEN SPECIFICATIONS

Conveyor Belt Width

32

″ (813mm)

Heating Zone Length

40-1/2

″ (1028mm)

Baking Area Square Feet

9 sq. ft. (0.84 sq. m.)

Overall Dimension
Standard Single Oven w/Legs

80

″ (2032mm) L ×

61-5/16

″ (1557mm) W ×

47-5/16

″ (1202mm) H ×

Overall Dimension
Double Oven

80

″ (2032mm) L ×

61-5/16

″ (1557mm) W ×

60-15/16

″ (1548mm) H x

Overall Dimension
Triple Oven

80

″ (2032mm) L x

61-5/16

″ (1557mm) W ×

77-1/2

″ (1969mm) H ×

Weight of Single Oven

925 lb (419kg)

Shipping Weight

1,100 lb (498.3kg)

Shipping Cube

Approx. 132 ft

3

(3.74 m

3

)

Operating Range

110,000 BTU/hr

(116.0 mJ/h)

(27,720 kcal)

(32.2 kW/hr)

Maximum Operating Temperature

550°F (287°C)

Warm-up Time

10 min.

Gas Oven Inlet Line Size

3/4

″ (19mm) ID for each oven

Minimum Gas Meter Rating

450 cu.ft./hr. (12.74m

3

h) for 1 to 2 ovens

Add 180 cu.ft./hr (5.1m

3

h) for each additional oven

Minimum Gas Pipe Size
Natural (must be dedicated line)

2

″ (51mm) ID for 1, 2, or 3 ovens

Propane (must be dedicated line)

2

″ (51mm) ID for 1, 2, or 3 ovens

Gas Pressure
Natural

6

″ to 12″ Water Column (13.8 to 29.9 mbar)

Propane

11.5

″ to 12″ Water Column (28.7 to 29.9 mbar)

Gas Valve

0.75

″ (19mm) ID full-flow, gas, shutoff valve installed in oven inlet gas line.

A separate connection and valve must be provided for each oven.

Recirculating Air Fan

One fan at 2300 RPM

Air Velocity

3000 fpm (1524 cm/sec) (Average)

Bake Time

3 min. 0 sec. Bake Time minimum

30 min. 0 sec. Bake Time maximum

SERIES PS540 ELECTRICAL SPECIFICATIONS

Main Blower &

Control Circuit

Phase

Frequency

Amperage

Poles

Wires

Elements Voltage

Voltage

Draw

208-240V

208-240V

1 Ph

50/60 Hz

4.1 Amp

3 Pole

3 Wire

(2 hot, 1 grd)

NOTE

Wiring Diagrams are contained in Section 7 of this Manual

and are also located inside the oven at the

bottom of the Control Panel

This Manual Must Be Kept For Future Reference

Inlet

1.13 kPa
2.75 kPa

Test Power

0.87 kPa
2.39 kPa

Advertising