Cabling and Hookup

1. Connect a fiber optic cable between the ADAT’s

lightpipe output and the D8B’s lightpipe input.
Likewise, connect the D8B’s lightpipe output to
the ADAT’s lightpipe input. (A DIO•8 or OPT•8
lightpipe card must be installed in the D8B to
gain access to the digital tape inputs and outputs.)

2. Connect the 9-pin D-sub sync cables between the

Sync Box (SYNC OUT) and the first ADAT’s
SYNC IN connector. Then connect the sync
cables in a daisy-chain fashion between the
remaining ADATs. Connect the SYNC OUT on
the last ADAT to the SYNC IN on the Sync Box
to complete the loop.

3. Connect MIDI cables between the MIDI OUT

connector on the Digital 8•Bus’ Remote CPU
and the MIDI IN connector on the Sync Box, and
between the MIDI IN connector on the Digital
8•Bus’ Remote CPU and the MIDI OUT
connector on the Sync Box.

Settings

D8B

1. Open the Setup window by pressing Ctrl+1 or

Setup in the bottom menu bar on-screen.

2. Click “Digital I/O” to open the Digital I/O

dialog box.

3. Click each Tape Input and Output box and select

ADAT for each DIO•8 card installed.

4. Set “Samplerate” to match the sample rate of

the formatted ADAT tapes (typically 48kHz or
44.1kHz).

ADATs

1. Select DIGITAL IN on the ADAT front panel.

M o d u l a r D i g i t a l M u l t i t ra c k

CLOCK

EXT

INPUT MON

INPUT

DIGITAL

48K

INPUT MONITOR

INPUT SELECT

AUTO

INPUT

ALL

INPUT

TRACK

COPY

DIGITAL

INPUT

Notes:
• When powering up, turn the Digital 8•Bus on first,
then turn the ADATs on.
• Make sure MMC and MTC are lit on the sync box.