Gb d f sw i nl e p, On/off, Selecting operation – MITSUBISHI ELECTRIC PEH-P10 User Manual

Page 6: Before starting operation, Start an operation, Stop an operation, Caution, When selecting operation, For cooling, For dry

Advertising
background image

6

GB

D

F

SW

I

NL

E

P

E

B

6

3

1

E

V

D
F

TIMER SET

PAR-20MAA

ON/OFF

CENTRALLY CONTROLLED

ERROR CODE

CLOCK

ON

OFF

˚C

CHECK

CHECK MODE

FILTER

TEST RUN

FUNCTION

˚C

1Hr.

NOT AVAILABLE

STAND BY
DEFROST

FILTER

CHECK TEST

TEMP.

3

2

E

C

A

1

6 87

4

B

A

Before starting operation

Start running after the “HO” display has disappeared. The “HO” display briefly
appears on the room temperature display (max. 3 minutes) when the power is
turned on and after a power failure. This does not indicate any failure of the air
conditioner.

During heating operation, even if the indoor unit is set to operation while the
outdoor unit is in defrosting operation, operation starts after the defrosting op-
eration of the outdoor unit has ended.

3.1. ON/OFF

Start an operation

1. Press the B

B

B

B

B [ON/OFF] button

Operation lamp

lights up and operation starts.

Stop an operation

1. Press the B

B

B

B

B [ON/OFF] button again

Operation lamp goes off and operation stops.

Once the buttons have been set, pressing of the [ON/OFF] button only can
repeat the same operation thereafter.

During operation, the operation lamp above the [ON/OFF] button lights up.

Caution:

Even if the operation button is pressed immediately after the operation is
once stopped, operation is not restarted for about 3 minutes. This function
protects the machine. It automatically starts operation after the lapse of ap-
proximately 3 minutes.

3.2. Selecting operation

When selecting operation

1. Press the 3

3

3

3

3 [selecting operation] button

Consecutive press of the selecting operation button switches the operation
over to E “

”, “

”, “

”, (“

”), and (“

”). For the contents of operation,

check the display.

For cooling

Press the 3

3

3

3

3 [selecting operation] button and bring up the “

” display.

For dry

Press the 3

3

3

3

3 [selecting operation] button and bring up the “

” display.

Dry operation cannot be carried out at a room temperature of less than 18

°C.

For fan

Press the 3

3

3

3

3 [selecting operation] button and bring up the “

” display.

The fan operation functions to circulate the air in the room.

The temperature of the room cannot be set by fan operation.

Caution:

Never expose your body directly to cool air for a long time. Excessive expo-
sure to cool air is bad for your health, and should therefore be avoided.

Dry operation

The dry is a microcomputer-controlled dehumidifying operation which controls ex-
cessive air-cooling according to the room temperature of your choice. (Not usable
for heating.)

1. Until reaching room temperature of your choice

The compressor and indoor fan function is linked motion according to the change
of the room temperature and automatically repeat ON/OFF.

2. When reaching room temperature of your choice

Both the compressor and indoor fan stop.

When stop continues for 10 minutes, the compressor and indoor fan are oper-
ated for 3 minutes to keep the humidity low.

For heating

Press the 3

3

3

3

3 [selecting operation] button to bring up the “

” display.

Regarding displays during heating operation “DEFROST”
Displayed only during the defrosting operation.

“STAND BY”
Displayed from the start of heating operation until the moment warm air blows out.

Remote controller-Button

PAR-20MAA

ON/OFF

CENTRALLY CONTROLLED

ERROR CODE

CLOCK

ON

OFF

˚C

CHECK

CHECK MODE

FILTER

TEST RUN

FUNCTION

˚C

1Hr.

NOT AVAILABLE

STAND BY
DEFROST

FILTER

CHECK TEST

TEMP.

TIMER SET

1

2

3

4 5 6 8 7 9

0

C

A

B

ON/OFF

CENTRALLY CONTROLLED

ERROR CODE

CLOCK

ON

OFF

˚C

CHECK

CHECK MODE

FILTER

TEST RUN

FUNCTION

˚C

1Hr.

NOT AVAILABLE

STAND BY
DEFROST

TEMP.

A

B

C

D

E

F

H

I KL J

M

P

N

O

R

S

Q

T

U

G

Remote controller-Display

1

[Room temperature adjustment] Button

2

[Timer/continuous] Button

3

[Selecting operation] Button

4

[Time selection] Button

[Time-setting] Button

5

[Louver] Button

6

[Fan speed adjustment] Button

7

[Up/down airflow direction] Button

8

[Ventilation] Button

9

[Checking/built-in] Button

0

[Test run] Button

A

[Filter] Button

B

[ON/OFF] Button

C

Position of built-in room temperature

Never expose the remote controller to direct sunlight. Doing so can result in
the erroneous measurement of room temperature.

Never place any obstacle around the lower right-hand section of the remote
controller. Doing so can result in the erroneous measurement of room tem-
perature.

A

Current time/Timer

B

Centralized control

C

Timer ON

D

Abnormality occurs

E

Operation mode:

COOL,

DRY,

AUTO,

FAN,

HEAT

F

Preparing for Heating mode

G

Defrost mode

H

Set temperature

I

Power ON

J

Louver

K

Not available function

L

Ventilation

M

Function setting mode

N

Test run mode

O

Error check mode

P

Filter sign

Q

Set effective for 1 hr.

R

Sensor position

S

Room temperature

T

Airflow

U

Fan speed

Advertising
This manual is related to the following products: