3 common parameters, 2) gain/filter parameters, Points – MITSUBISHI ELECTRIC MOTION CONTROLLERS Q172DCPU User Manual

Page 89

Advertising
background image


3 - 20

3 COMMON PARAMETERS

(2) Gain/filter parameters

No. Symbol

Name

Initial

value Unit

PB01

FILT

Adaptive tuning mode (Adaptive filter ) 0000h

—

PB02

VRFT

Vibration suppression control tuning mode (Advanced vibration suppression control)

0000h

—

PB03

—

For manufacturer setting

0

—

PB04

FFC

Feed forward gain

0

%

PB05

—

For manufacturer setting

500

—

PB06

GD2

Ratio of load inertia moment to servomotor inertia moment

7.0

times

PB07

PG1

Model loop gain

24 rad/s

PB08

PG2

Position loop gain

37

rad/s

PB09

VG2

Speed loop gain

823 rad/s

PB10

VIC

Speed integral compensation

33.7

ms

PB11

VDC

Speed differential compensation

980

—

PB12

—

For manufacturer setting

0

—

PB13

NH1

Machine resonance suppression filter 1

4500

Hz

PB14

NHQ1

Notch shape selection 1

0000h

—

PB15

NH2

Machine resonance suppression filter 2

4500

Hz

PB16

NHQ2

Notch shape selection 2

0000h

—

PB17 —

Automatic

setting

parameter

—

—

PB18

LPF

Low pass filter setting

3141

rad/s

PB19

VRF1

Vibration suppression control - vibration frequency setting

100.0

Hz

PB20

VRF2

Vibration suppression control - resonance frequency setting

100.0

Hz

PB21

0.00

PB22

—

For manufacturer setting

0.00

—

PB23

VFBF

Low pass filter selection

0000h

—

PB24 MVS

Slight vibration suppression control selection

0000h

—

PB25

—

For manufacturer setting

0000h

—

PB26 CDP

Gain changing selection

0000h

—

PB27

CDL

Gain changing condition

10

—

PB28

CDT

Gain changing time constant

1

ms

PB29

GD2B

Gain changing - ratio of load inertia moment to servo motor inertia moment

7.0

times

PB30

PG2B

Gain changing - position loop gain

37

rad/s

PB31

VG2B

Gain changing - speed loop gain

823

rad/s

PB32

VICB

Gain changing - speed integral compensation

33.7

ms

PB33

VRF1B

Gain changing - vibration suppression control - vibration frequency setting

100.0

Hz

PB34

VRF2B

Gain changing - vibration suppression control - resonance frequency setting

100.0

Hz

PB35

0.00

PB36

0.00

PB37

100

PB38

0.0

PB39

0.0

PB40

0.0

PB41

1125

PB42

1125

PB43

0004h

PB44

0.0

PB45

—

For manufacturer setting

0000h

—

POINTS

(1) When the items marked " " in the above table has changed, make the Multiple

CPU system reset or power supply OFF to ON. And, once turn OFF the servo
amplifier power supply and then turn ON it again.

Advertising
This manual is related to the following products: