Power, Environmental, Input v @1.0 a, 5 w average – METRObility Optical Systems RADIANCE R231-1Y User Manual

Page 21

Advertising
background image

Radiance Access Line Cards 21

Singlemode CWDM F/O Interface (R231-47, -49, -51, -53, -55, -57, -59, -61)
Connector _____________________________________________________ LC
Wavelength ________________________________________ (see tables below)
Supported Link Length __________________________ up to 60 km full duplex
Cable Type ___________________________________________ 9/125

µ

m F/O

RX Input Sensitivity _______________ -25 dBm (typical); -23 dBm (maximum)
Output Power ___________________________ -3 to +2 dBm; -1 dBm (typical)

r

e

b

m

u

N

l

e

d

o

M

h

t

g

n

e

l

e

v

a

W

r

e

b

m

u

N

l

e

d

o

M

h

t

g

n

e

l

e

v

a

W

7

4

-

1

3

2

R

m

n

0

7

4

1

5

5

-

1

3

2

R

m

n

0

5

5

1

9

4

-

1

3

2

R

m

n

0

9

4

1

7

5

-

1

3

2

R

m

n

0

7

5

1

1

5

-

1

3

2

R

m

n

0

1

5

1

9

5

-

1

3

2

R

m

n

0

9

5

1

3

5

-

1

3

2

R

m

n

0

3

5

1

1

6

-

1

3

2

R

m

n

0

1

6

1

Multimode F/O Interface (R231-13, R231-15)
Connector ________________________________________________ ST or SC
Wavelength _______________________________________________ 1310 nm
RX Input Sensitivity ________________________________ -31 dBm minimum
Output Power _______________________ -23.5 dBm to -14 dBm (50/125

µ

m)

_______________________ -20 dBm to -14 dBm (62.5/125

µ

m)

Supported Link Length ___________________________ up to 2 km full duplex
Cable Type ________________________________ 50/125 or 62.5/125

µ

m F/O

Twisted-Pair Interface
Connector __________________________________ Shielded RJ-45, 8-pin jack
Impedance ________________________________________ 100 Ohms nominal
Signal Level Output (differential) __________________________ .95 to 1.05 V
Signal Level Input _________________________________ 350 mV minimum
Supported Link Length ________________________________________ 100 m
Cable Type _________________________________________ Category 5 UTP

(For NEBS Level III and EN55024:1998 compliance, use only
Category 5 STP cables.)

Power

Input _______________________________________ 5 V @1.0 A, 5 W average

Environmental

Operating Temperature ____________________________________ 0

°

to 55

°

C

Storage Temperature ____________________________________ -30

°

to 70

°

C

Operating Humidity _________________________ 5% to 95% non-condensing
Weight _______________________________________________ 5 oz (0.14 kg)

Advertising