3-5-2. Special Status request and Status answer list

Request Status

Char. & Sample

Status answer

Char. & Sample

SERIAL NUMBER

‘n’ ("@1?n", 0x0D)

SERIAL NUMBER

“n0XXXXXXXXX”
("@1n0123456789",0x0D)

see blow

m0#$%&
(“@1m0#$%&”,0x0D)

ERROR DETECT

‘m’ ("@1?m", 0x0D)

No error

m- (“@1m-“,0x0D)

Descriptions of ERROR DETECT status answer character. (about : #$%&)
(Character #, $, % and & would be ‘0’ to ‘9’ or ‘A’ to ‘F’, it uses to as hex. bit data.)
* # : Bit ErrorName ERROR

SAFE

3 Reserved

1

1

2 Reserved

0

0

1 Reserved

0

0

0 Reserved

0

0


* $ : Bit ErrorName ERROR

SAFE

3 Reserved

0

0

2 Reserved

0

0

1 PROTECT

1

0

0 DSP1 ERROR

1

0


* % : Bit ErrorName ERROR

SAFE

3 Reserved

1

1

2 DSP2 ERROR

1

0

1 ADC ERROR

1

0

0 EEPROM ERROR

1

0


* & : Bit ErrorName ERROR

SAFE

3 EEPROM IF ERROR

1

0

2 DSP CODE ERROR

1

0

1 RS232C ERROR

1

0

0 POWER 5V ERROR

1

0


ex.)
* If the POWER 5V ERROR only occurs that will send [“@1m08081”,0x0D].
* If the RS232C ERROR only occurs that will send [“@1m08082”,0x0D].
* If the ADC ERROR only occurs that will send [“@1m080A0”,0x0D].
* If the DSP1 ERROR only occurs that will send [“@1m09080”,0x0D].