Displaying settings, Storing a dialing command, Configuration, storing a – Multi-Tech Systems MT5634ZBA User Manual

Page 19: Data set ready control command, Display current settings command, Dsr control command, Select maximum mnp block size command, Store current configuration command, Store dialing command, V.54 tests

Advertising
background image

Chapter 4 - AT Commands, S-Registers, Result Codes

19

MultiModemDID User Guide

Command:

&S

n

Data Set Ready (DSR) Control

Values:

n = 0 or 1

Default:

0

Description:

&S0

DSR is always high (on).

&S1

DSR goes high only during a connection.

Command:

&T

n

V.54 Test Commands

Values:

n = 0, 1, 3 or 6

Default:

None

Description:

&T0

Abort. Stops any test in progress.

&T1

Initiates local analog loopback test.

&T3

Initiates local digital loopback test.

&T6

Initiates remote digital loopback test.

Note: To stop a test, you must use the escape sequence (+++AT) before typing
&T0.

Command:

&V

Display Current Settings

Values:

n/a

Description:

Displays the active modem settings, including the callback
security settings if callback security is enabled. If the setup
password has been entered, it also displays the callback
security passwords.

Command:

&W

n Store Current Configuration

Values:

n = 0, 1

Default:

1

Description:

&W0 Stores current modem settings in nonvolatile memory and

causes them to be loaded in place of the factory defaults at
power-on or following the ATZ command. See also the &F
command.

&W1 Clears user default settings from nonvolatile memory and

causes the factory defaults to be loaded at power-on or
following the ATZ command.

Command: &Z

n=x Store Dialing Command

Values:

n = 0, 1, 2 (callback security disabled)
x = Dialing command string

Default:

None

Description:

Stores dialing command

x in memory location y. Dial the stored

number using the command ATDS=

n. See also the #CBSn

command.

Command:

\A

n

Select Maximum MNP Block Size

Values:

n = 0, 1, 2, or 3

Default:

3

Description:

\A0

64-character maximum.

\A1

128-character maximum.

\A2

192-character maximum.

\A3

256-character maximum.

Advertising