Vermont castings ewf36a, Mantels, Side wall protection – Majestic Appliances EWF36A User Manual

Page 15: Hearth installation

Advertising
background image

15

Vermont Castings EWF36A

20005167

Must be sealed with
noncombustible material

Mantel Shelf

Side View

Finished Wall

2 x 4 Stud

Standoff

Cast Front

See mantel drawing for
shelf-to-grille dimension

1” (25mm)

Fireplace
Front (Steel)

2 x 4 Stud

FP1200

Fig. 20 Finishing materials placement.

Brick Ledge

Noncombustible Finish
Material Only in this Area

Top View

Mantels

The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.

For the correct mounting heights and widths, refer to
Figures 21 and 22. When using paint or lacquer to
finish the mantel, such paint or lacquer must be heat
resistant to prevent discoloration.

Side Wall Protection

Adjacent combustible side walls that are within mini-
mum dimensions shown in Figure 24 of the fireplace
opening must be protected with Majestic Wall Shield
Model SP40 or a specifically built wall shield described
in Figure 19.

The special wall shield design described in Figure 19 is
an alternate method of adding protection to side walls
and can be used in place of the SP40 with the same
wall clearances specified for the SP40. Rt must =1.85
minimum.

Examples of wall shield insulation:

1. Manville - CERAFORM 126, K=.27,

1/2 inches thick

2. EH2416, K = .458,

1 inch thick required.

Hearth Installation

A hearth extension is required to protect a combustible
floor in front of the fireplace. Refer to Figure 25 for
minimum dimensions and mounting detail.

NOTE: Hearth Extension must not cover the air
inlet opening of a fireplace.

The hearth extension described in Figure 25 must be a
durable noncombustible material with a minimum (total)
Rt value of 1.09; see Figure 23 for examples. The
overall height (above a combustible floor), depth and
width must be as indicated, with the extension centered
to the fireplace opening.

FP1398

Fig. 21 Combustible mantel minimum opening.

6"

(159mm)

Min.

12"

(305mm)

Min.

1

¹⁄₂

"

(38mm)

12"

(305mm)

Max.

Combustiible
Mantel and
Trim

Finished Wall

Header

Standoff

Noncombustible
Material

Brick Ledge

GrilleOpening

Fireplace
Front

MA81

Fig. 22 Combustible mantel clearances.

*

1

¹⁄₂

"

Ref.

**

Combustible materials
are permitted within a
shaded area shown in
Figure 25 titled
Minimum Wall
Clearances

* 12” (305mm) from top of grille opening.