The pyrolysis of wood produces certain substances

which will not burn unless the temperature in the firebox

reaches 1000°F or higher. Under normal conditions

these temperatures are not attained and these sub-

stances simply escape up the chimney as wasted energy

and can form deposits in the chimney. By forcing these

unburned substances to come into contact with a cata-

lyst, we can cause them to burn at much lower tempera-

tures that are easily attainable during normal operation.

Installation and removal of the combustor is simple, the

element fits inside a retainer. The retainer fits inside the

furnace exhaust pipe which extends down into the fire-

box. The assembled combustor slides up into the ex-

haust pipe stub which protrudes down into the firebox.

There are three rods on the retainer which engage slots

in the pipe and then turn slightly to lock in place. These

rods are not symmetrical. Two rods are welded together

to form a 90° angle. This angle points toward the rear of

the firebox.

SLOTS IN EXHAUST PIPE

CATALYTIC ELEMENT

RODS ON RETAINER

FIGURE 18 INSTALL OPTIONAL CATALYTIC

COMBUSTOR (MODEL 2900/4000)

ASSEMBLE MANUAL DRAFT

MODEL 526 ONLY

Using a 1/4x1-1/2 bolt and locknut, mount manual draft

control onto the draft channel, figure 19. If you are going

to install optional forced draft, disregard. Do not tighten

too tight to damper draft adjustment, but not too loose to

let more air in than required. DO NOT remove knockout

on draft channel. Locknut can be held with wrench in-

serted through air opening.

INSTALL COMFORT CONTROL CENTER

AND FORCED DRAFT BLOWER

1. Install all knobs to control levers and door handles.

See figure 20.

2. The comfort control center is factory wired to the

fan/limit control and the forced draft blower. It has a

prewired flexible conduit for connection to the circulating

blower.

3. If you have optional temperature gauge on your con-

trol, then strip ½" of insulation from the two leads of ther-

mocouple wire protruding through the rectangular

opening on the furnace side. Connect these leads to the

terminals on the temperature gauge of the control. IM-

PORTANT: Remove the wire ground clip from the termi-

nals of the gauge and connect White wire to + terminal

and Red wire to - terminal. See figure 22.

4. Mount the control to the side of the furnace with four

#10 sheet metal screws.

5. Remove the knockout section of the draft channel on

model 526 by striking sharply with a hammer. Be careful

so you do not damage the mechanism inside the chan-

nel and directly behind the knock-out. DO NOT allow the

knock-out to fall inside the draft channel.

6. Align the forced draft blower outlet flange over the

knockout and secure with three #10 sheet metal screws.

7. Secure conduit to furnace side using conduit clamps

and #10 sheet metal screws.

FIGURE 19 INSTALL MANUAL DRAFT-MODEL 526

1/4 LOCKNUT

DO NOT REMOVE

KNOCKOUT

MANUAL DRAFT

CONTROL

1/4x1-1/2 BOLT