Metrologic Instruments IS4921 User Manual

Page 41

Advertising
background image

35

DC Operating Voltages

Signal Signal

Description

MIN

MAX

Condition

VIN

Operating Voltage

3V

5.5V

VIH(1)

Input High (RX, CTS)

2.5V

VIL(1)

Input Low (RX, CTS)

.8V

VIH(2)

Input High (TTL_INV, nWake)

.8xVIN

VIL(2)

Input Low (TTL_INV, nWake)

.8V

VIH(3)

Input High (Trigger)

.8xVIN

VIL(3)

Input Low (Trigger)

.25V

VOH(1)

Output High Voltage (TX,RTS)

.8xVIN

Isource = 16 mA

VOL(1)

Output Low Voltage (TX,RTS)

.14xVIN

Isink = 16 mA

VOH(2)

Output High Voltage (nBeeper, nGoodRead)

***

5.5V

VOL(2)

Output Low Voltage (nBeeper, nGoodRead)

.6V

Isink = 25 mA

VOH(3)

Output High Voltage (Power down)

***

5.5V

VOL(3)

Output Low Voltage (Power down)

.2V

Isink = 8 mA

*** PWRDWN, nGoodRead, and nBeeper are open drain outputs w/ 100K pull-ups to VIN. Actual VOH will be

determined by the parallel resistance of the 100K pull up and any external impedance.

Current Draw @ 25°C

USB TTL

Signal Signal

Description

VIN = 3.3V

VIN = 5V

VIN = 3.3V VIN = 5V

Continuous
Scan mode

Average current draw during continuous
scan mode*

235 mA

175 mA

200 mA

140 mA

Idle

Average current draw while in idle mode

160 mA

120 mA

125 mA

85 mA

Sleep

Average current draw while in sleep mode

65 mA

65 mA

25 mA

25 mA

Suspend
Mode (USB)

Average current draw in USB suspend
(USB version only)

600 µA

650 µA

N/A

N/A

Power Down
Mode (TTL)

Average current draw in power down mode
(TTL Version Only)

N/A

N/A

500 µA

500 µA

* Note: Continuous Scan Mode current will vary based on object size, distance, and type. The numbers listed

above are typical.

Advertising