Fp2507 vfs dbx controls – Monessen Hearth DFX24C User Manual

Page 5

Advertising
background image

33D4047

5

DFX & DBX Series Vent Free Fireplaces

PRODUCT FEATURES

This vent-free fireplace must be mounted on the floor or
on the optional fireplace hearth.

OPERATION

This unvented gas heater requires no outside venting and
burns cleanly with high heating efficiency.
This zero-clearance unvented gas heater can be installed
against (or recessed into) any wall that is accessible to a
gas line.

FP2507
VFS DBX controls

Piezo
Ignition

Fireplace
Screen

Control
Knob

Figure 1 -
Unvented Gas Heater
(Control Access Door Shown Open)

On/Off Switch

FP507

GAS PRESSURES

Manual &

Control

Fuel

T-stat

Millivolt

Regulator Pressure

Nat.

4.0” w.c.

3.5” w.c.

Pilot Regulator

Nat.

n/a

3.5” w.c.

Max. Inlet Pressure

Nat.

10.5” w.c.

10.5” w.c.

Min. Inlet Pressure

Nat.

5.0” w.c.

5” w.c.

Regulator Pressure

LP

10.0” w.c.

10.0” w.c.

Max. Inlet Pressure

LP

13.0” w.c.

13.0” w.c.

Min. Inlet Pressure

LP

11.0” w.c.

11.0” w.c.

Input BTU/hr

Model

Fuel Control

Max. Min.

4DFXNMC Nat.

Manual

,000 15,000

4DFXPMC

LP

Manual

,000 17,000

4DFXNVC

Nat.

Millivolt

,000 17,000

4DFXPVC

LP

Millivolt

,000 17,000

3DFXNVC

Nat.

Millivolt

6,000 0,000

3DFXPVC

LP

Millivolt

6,000 0,000

DBX4NTC

Nat.

T-Stat

10,000

--

DBX4PTC

LP

T-Stat

10,000

--

GAS SPECIFICATIONS

NOTE: For LP models an external regulator is required
to reduce supply pressure to a maximum of 13" w.c.

IGNITION CONTROLS

Piezo ignitor allows ignition of the pilot without the use of
matches or batteries.
Manual control has four (4) positions:

OFF - All gas to the gas logs is shut off at the

valve.

IGN - Valve position to light/maintain a standing

pilot.

ON - Valve position to turn ON/OFF log set with

remote switch/thermostat.

LOW/HI - Variable position to control flame height

(heat output). Both front and rear burners

are in operation to provide realistic glow

and yellow flame.

Thermostat control has three (3) positions:

OFF - All gas to the gas logs is shut off at the

valve.

IGN - Valve position to light/maintain a standing

pilot.

LOW/HI - Variable position corresponding to desired

temperature.

PILOT

The gas log heater is fitted with a specially designed safety
pilot light which senses the amount of oxygen available in
the room and shuts the gas log heater off if the oxygen level
begins to drop below a satisfactory level. The pilot can only
be relit when adequate fresh air is available.

THERMAL GENERATOR

The millivolt gas log pilot is fitted with a millivolt generator
to provide power for remote activation.