Scanner Pinout Connections
The MS7220 scanner interfaces terminate to 10-pin modular jacks located on
the back of the unit. The serial # label indicates the interface enabled when the
scanner is shipped from the factory.
Figure 15: EAS Scanner Interface Ports
MS7220-13
OCIA
MS7220-13
IBM 46xx
Pin
Function
Pin
Function
1
Ground
1
Ground
2
NC
2
RS232 Transmit Output
3
NC
3
RS232 Receive Input
4
RDATA
4
RTS Output
5
RDATA Return
5
CTS Input
6
Clock in
6
DTR
7
Clock out
7
IBM B- (D-)
8
Clock in Return/
Clock out Rtrn
8
IBM A+ (D+)
9
+5VDC
9
+5V IN
10
Shield Ground
10
NC