Scanner and cable terminations – Metrologic Instruments Laser Scanner User Manual

Page 46

Advertising
background image

42

S

CANNER AND

C

ABLE

T

ERMINATIONS

Scanner Pinout Connections

The MS7220 scanner interfaces terminate to 10-pin modular jacks located on
the back of the unit. The serial # label indicates the interface enabled when the
scanner is shipped from the factory.

Figure 15: EAS Scanner Interface Ports

MS7220-13

OCIA

MS7220-13

IBM 46xx

Pin

Function

Pin

Function

1

Ground

1

Ground

2

NC

2

RS232 Transmit Output

3

NC

3

RS232 Receive Input

4

RDATA

4

RTS Output

5

RDATA Return

5

CTS Input

6

Clock in

6

DTR

7

Clock out

7

IBM B- (D-)

8

Clock in Return/
Clock out Rtrn

8

IBM A+ (D+)

9

+5VDC

9

+5V IN

10

Shield Ground

10

NC

Continued next page