Normal condition

POWER

STATUS

CONDITION

NOTE

Steady

red

Off

Stand-by

Steady

green

Blinking

green

Lamp stand-by (about 1 minute)

The POWER button cannot be used to
switch between on and off.

Steady

green

Steady

green

The power is on. (Normal condition)

Abnormal condition

POWER

STATUS

CONDITION

POSSIBLE SOLUTION

Steady

green

or

Steady

red

Blinking orange

Abnormal temperature

The ventilation grilles are clogged with dust or dirt.
The room temperature is high.


Clean the ventilation grilles.
Relocate the projector to a cooler place.


Steady

red

Blinking green

The protection circuit is working or the lamp is in an
abnormal condition.

Wait until the STATUS indicator goes out,
then press the POWER button.
If the above solution is not effective,
replace the lamp.

Steady

green

Blinking green/red

Lamp operation time warning. (Total lamp operation
time reached 3750 hours*

1

while the power was on.)

Replace the lamp.
Change with a new lamp if this problem
recurs.

Steady

red

Blinking red

Lamp operation time warning. (Total lamp operation
time reached 3750 hours*

1

while the power was off.)

Steady

red

Steady red

Lamp operation time warning. (Total lamp operation
time reached 5000 hours*

1

*

2

while the power was off.)

Blinking

green/red

Off

The lamp cover isn’t closed.

Close the cover correctly.

Blinking

green/red

Steady

or

Blinking

Abnormal.

Contact your dealer.

*

1

Duration when LAMP MODE of the INSTALLATION menu is set to LOW. When it is set to STANDARD, this duration will be

shorted.

*

2

Duration when LAMP MODE is set to STANDARD, this duration will be shorted up to 2000 hours.