Cleaning and maintenance – Mastic Spark Modern Fires 91P User Manual
Page 35

36
L100001
35
CLEANING AND MAINTENANCE
VENT SYSTEM
The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person.
Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow. Inspect entire venting
system to ensure proper function.
GLASS
PANELS
Thoroughly clean the inside of the glass
panels
after using the fireplace for ten hours. Periodically clean the glass
panel
as neces-
sary.
When cleaning the glass, remember:
• Do not remove the glass when hot. Allow glass to cool before removal.
• NEVER use abrasive materials.
• Keep children and pets a safe distance away.
• Never operate the fireplace without the glass door properly secured.
• Never operate the fireplace if the glass is broken.
• Replace any glass that is chipped, cracked, or broken. Replacement glass door assemblies MUST be supplied by the fireplace
manufacturer – No substitute materials may be used.
• Handle glass door with care to avoid striking or scratching it on hard objects.
To clean glass door, follow “Glass Removal” procedure outlined in the Final Installation section. Film deposit on the inside of
the glass should be cleaned off using a nontoxic, non-corrosive, non-abrasive, mild-cleaning solution. Simply apply an adequate
amount to the glass and wipe off with a damp cloth. After all maintenance has been completed, re-install glass door.
STONES
Leave
stones
installed in the fireplace for cleaning. Vacuum surface of the
st ones
with a brush attachment. If
stones
must be
removed
for cleaning, handle carefully by holding gently.
MEDIA
Replace or add media as required following unstallation instructions in the Final Installation section of this manual
.
BLOWER/FAN ASSEMBLY
The fan assembly has an automatic temperature control which will turn the fan on as the fireplace heats up. The fan will turn off as
the fireplace cools down. The control knob can be used to turn the fan off or control the fan speed. The heat up time and cool down
time is controlled by the temperature disc magnetically mounted under the fireplace bottom. This disc can be moved to adjust the
blower start up and shut off timing.
CAUTION: Label all wires
prior to disconnection when
servicing controls. Wiring errors
can cause improper and dan-
gerous operation. Verify proper
operation after servicing.