1 introduction, Multimodemzpx user guide – Multi-Tech Systems MULTIMODEM MT5634ZPX-V.92-ISA User Manual

Page 9

Advertising
background image

1 Introduction

9

MultiModemZPX User Guide

Command Buffer

40 Characters

Transmission Level

-11 dBm (North America and Pan Euro) - varies by country setting

Frequency Stability

±0.01%

Receiver Sensitivity

-43 dBm under worst-case conditions

AGC Dynamic Range

43 dB

Connectors

One RJ-11 phone jack

Cables

One modular telephone cable (USA); country-specific cord for UK
and International models; one 9-pin to 25-pin serial cable for UK
and International models; external power transformer and cord

Diagnostics

Local analog loop, local digital loop, remote digital loop

Environmental

Temperature range 0°–50°C (32°–120°F);
humidity range 20–90% (non-condensing)

Storage Temperature

-10° to +85°C (14°- 185° F)

Dimensions

10.8 cm wide x 14.8 cm long x 2.9 high (4.25” × 5.8” x 1.15”)

Weight

224 g (8 oz)

Operating Systems

Tested for use with Windows 95, 98, NT, and 2000, and Linux
(2.2.x kernal)

Limited Warranty

2 years