Manitowoc Ice FLARE NUT TXV REPLACEMENT (Z100) 7625563 User Manual

Manitowoc Ice Freezers

Advertising
background image

7625563

FLARE NUT TXV REPLACEMENT (Z100)

Installation Instructions


1. Disconnect power from reach-in.
2. Recover refrigerant.
3. Remove armaflex insulation from existing expansion valve.
4. To remove expansion valve, loosen flare nuts from expansion valve.
5. Unsweat flare nuts’ extensions at solder joints.
6. NOTE: WRAP NEW TXV WITH WET CLOTH TO PREVENT OVERHEATING VALVE. Slip copper extensions

into TXV and swaged ends onto existing lines and sweat into place.

7. When TXV is cool, slip rubber boot over TXV and glue seam together.
8. Evacuate and weigh in proper charge.





















Manitowoc Ice, Inc.

2110 South 26 Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA
Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879 8009613
Web Site -

www.manitowocice.com

Rev. 08/24/99