Ac current, Return amplifier, Adu automatic drive unit – Motorola BLE100 User Manual
Page 45

A-2
Specifications
BLE100 Installation and Operation Manual
AC Current
AC Voltage
One-way
With RA-Kit
90 VAC
0.48 A
0.56 A
75 VAC
0.50 A
0.59 A
60 VAC
0.56 A
0.65 A
53 VAC
0.60 A
0.70 A
45 VAC
0.67 A
0.78 A
38 VAC
0.75 A
0.88 A
Return Amplifier
Parameter Specification
Passband (S-split)
5 through 40 MHz
Gain, station (minimum)
24 dB
Flatness
±0.50 dB maximum
Level control
Fixed pads, JXP-
∗B, input and output
Performance
at typical output
35 dBmV, flat
Channels
6 NTSC
Crossmod
–70 dB
CTB
–80 dB
CSO
–81 dB
Noise figure
6 dB
Power requirements
24 VDC, 125 mA
ADU Automatic Drive Unit
Parameter Specification
Pilot channel
See current catalog
Adjacent channel frequency
±6 MHz
Minimum BLE100 output at pilot
frequency
+36 dBmV
ALC stiffness
±0.3 output change for ±3.0 dB input change
Power requirement
24 VDC, 75 mA