SYMPTOMS POSSIBLE

CAUSE(S)

SOLUTION

The bar code may
have been printed
incorrectly.

Check if it is a check
digit/character/or border
problem.

The scanner is not
configured correctly for
this type of bar code.

Check if check digits are set
properly.

Scanner beeps
at some bar
codes and NOT
for others of the
same bar code
symbology.

The minimum symbol
length setting does not
work with the bar code.

Check if the correct minimum
symbol length is set.

Dirt could be preventing
the button from
compressing fully.

Make sure the button area is
clean and the button can move
freely.

Multi-Function
Button is not
working.

A faulty push button
switch.

Contact a Metrologic Customer
Service Representative.

Keyboard Wedge Only

The unit scans
the bar code but
there is no data.

Configuration is not
correct.

Make sure the scanner is
configured for the appropriate
mode.

The unit scans
but the data is
not correct.

Configuration is not
correct.

Make sure that the proper PC
type AT, PS2 or XT is selected.
Verify correct country code and
data formatting are selected.
Adjust the intercharacter delay
SYMPTOM.

The unit is
transmitting
each character.

Configuration is not
correct.

Increase the interscan code
delay setting. Adjust whether the
F0 break is transmitted. It may
be necessary to try this in both
settings.

Alpha characters
show as lower
case.

Computer is in Caps
Lock mode.

Enable Caps Lock detect setting
of the scanner to detect whether
the PC is operating in Caps Lock.