Maintenance instructions continued, Weekly maintenance spring cleaning – Nesco 6033 User Manual

Page 19

Advertising
background image

USSC

19

Maintenance Instructions Continued...

SPECIAL CLEANING/OPERATIONAL INSTRUCTIONS:
After cleaning or when operating the unit you need to make sure that the clean-out plates are in the closed position.

Push the front (2) clean-out slides all the way in and make sure that you have replaced the left & right clean-out plates

that are located on the inside of the unit (these plates are located inside the firebox to the left and right of the firepot in

the lower corners of the firebox). If these plates are not in the closed position the unit will burn dirty.

The 6033 has (2) front

cleanout slides that must be

in the closed position when

burning the unit.

The 6033 has a heat ex-

changer tube cleaning rod to

clean daily.


Set the stove on high fire. Open the draft to 100% and allow the stove to burn for 15 minutes. Resume desired heat and

draft setting.
Shut down the stove as directed in the operating instructions. Allow the stove to cool to room temperature. Remove the

small clean-out slides in the lower corners of the firebox. Tap the sides of the burn chamber with a wooden stick. Do not

tap the firewall behind the burn box as it may damage the insulation. Scrape the fly ash from the clean-out chambers

toward the front of the burn chamber. Remove the fly ash from the burn chamber and replace the clean-out chamber

doors.
Remove the ash pan and dump the ash into a metal container.
Cleaning of the exhaust system will depend upon the ash and debris content of your fuel. If your fuel has a high ash

content and/or significant debris in it, your exhaust system will require weekly cleaning. Cleaner fuels will allow for

monthly cleaning of the exhaust system. Remove the exhaust pipe from the back of your stove and remove any ash that

may have collected in the pipes. Replace the pipes to the stove and seal with high temperature seal tape. If you have

installed proper clean out tees you will not have to take the chimney sections apart.
While you are doing your weekly cleaning, have the unit set on high and the draft knob all the way out. Remember the

unit is not burning. After cleaning, push the draft knob back into the closed position.

REMEMBER: A clean unit burns efficiently and will remain trouble free!

Weekly Maintenance

SPRING CLEANING:

When the heating season is over make sure that you clean out all of the fuel in the hopper, firebox area, ash pan and firepot

area. Corn and any ash can accumulate moisture over the summer months causing the unit to rust and the fuel to mold.
It is recommended that prior to shutting down the unit in the spring, run the unit on the higher settings for a day to help clean

out the heat exchanger system, venting system and firebox area.
When the unit is cleaned out, take the venting apart, clean out the fly ash, rinse the venting out with a water hose and let dry,

take the draft blower off and clean, clean out all areas such as back heat exchanger and lubricate the auger, auger tube,

firepot area, fuel stirrer shaft and bearings and hopper area with a light oil (something like Pam cooking oil works great to

coat the inside of the unit and the moving parts). Clean the glass, doors and outer cabinet so that you are ready for the next

heating season.

Advertising