3 configuring the raa100, Raa100 user’s manual, 1 configuring rudder instance number – Maretron M001101 User Manual

Page 10

Advertising
background image

RAA100 User’s Manual

Page 6

Revision 1.0

end of the cable to the RAA100 (note the key on the male connector and keyway on the
female connector). Be sure the cable is connected securely and that the collar on the cable
connector is tightened firmly. Connect the other end of the cable (male) to the NMEA 2000

®

network in the same manner. The RAA100 is designed such that you can plug or unplug it
from an NMEA 2000

®

network while the power to the network is connected or disconnected.

Please follow recommended practices for installing NMEA 2000

®

network products.

Figure 4 – NMEA 2000

®

Connector Face Views

3 Configuring the RAA100

The RAA100 has several configurable parameters, which are shown below including the
default values. If you are not using the default values, then you will need to refer to the
corresponding section for configuring the RAA100 appropriately.

1. Rudder Instance Number – Default is Rudder Instance #0 (Section 3.1)
2. Operating Mode – Default is NMEA 2000

®

Mode (Section 3.2)

3. Resistive Sender – Default is American standard (Section 3.3)


In addition to configurable parameters, the RAA100 can be calibrated for standard resistive
senders (i.e., American standard 240-30 ohm, European standard 10-180 ohms) with
maximum rudder angles of 45°, or the RAA100 can be custom calibrated for any sender or
maximum rudder angles. Refer to Section 3.3 for choosing a standard type resistive sender or
custom calibrating the RAA100.

3.1 Configuring Rudder Instance Number

As shipped from the factory, the RAA100 transmits the Rudder Instance Number as “0”. The
NMEA 2000

®

network supports up to 252 rudders (0 through 251). The RAA100 is configured

or programmed by choosing a RAA100 rudder instance number using a display product such
as the Maretron DSM200. Refer to the user’s manual for configuring the RAA100 as the
manual provides detailed instruction on configuration procedures.

Advertising