Troubleshooting (cont’d) – Meco Aussie Portable LP 2200 User Manual

Page 14

Advertising
background image

Problem

Humming or whistling

from the regulator

Possible Cause

Outside temperature, humidi-
ty, barometric pressure, and
the gas level within the tank
may cause the rubber
diaphragm inside the regula-
tor to vibrate, making a hum-
ming or whistling sound.

Solution

Although this sound may be alarming, this is NOT dangerous as
long as it is not accompanied by the smell of gas. Simply adjust
the burner settings and usually the sound will subside. If the
humming sound persists, a change in atmospheric conditions will
eventually stop the vibration. Should you smell gas, do not use
the grill and call Customer Service at 1-800-251-7558

If your problem is not resolved from the information provided above, please call Customer Service at

1-800-251-7558.

14

Low flame or low heat

Gas in LP cylinder is low

Check LP gas cylinder. Replace if necessary.

TROUBLESHOOTING (cont’d)

Flames blow out

High or gusting winds

Gas in LP cylinder is low

Turn front of grill away from wind or increase flame height.

Check LP gas cylinder. Replace if necessary.

Flare up

Grease build up

Excessive fat in meat

Clean grill

Trim fat from meat before grilling

Persistent grease fire

Grease trapped in Bowl and
around burner system

Turn Control Knobs “OFF”. Let fire burn out and remove Cooking
Surfaces. After the grill cools, clean all parts.

LP gas cylinder is empty

Obstructions in burner

Dispose of empty cylinder and replace with a full one.

Clean burner (See How to Clean the Burners in Care and
Maintenance section of this manual).

Burner will not light

using a match

Excess flow valve tripped in
Regulator

Turn Control Knob to “OFF” position. Wait five minutes. Relight
LP gas grill. If flame remains to be low, turn off gas. Disconnect
the Lp gas cylinder from the Regulator. Reconnect the LP gas
cylinder to the Regulator. Perform a leak test. Relight grill. This
will reset the excess flow valve.

Wire is shorting (sparking
between ignitor wire and
electrode

Replace ignitor wire/electrode assembly (Call the Customer
Service Department @ 1-800-251-7558)

Burner not assembled
correctly

Excess flow valve tripped in
Regulator

Obstructions in burner

Electrode and burner are wet

Wire is loose or disconnect-

See burner re-assembly in How to Clean the Burners.

Turn Control Knob to “OFF” position. Wait five minutes. Relight
LP gas grill. If flame remains to be low, turn off gas.
Disconnect the Lp gas cylinder from the Regulator. Reconnect
the LP gas cylinder to the Regulator. Perform a leak test.
Relight grill. This will reset the excess flow valve.

Clean burner (See How to Clean the Burners in Care and
Maintenance section of this manual).

Dry electrode with clean cloth

Reconnect the wire

Advertising