Connecting the Data Lines
10/100BaseT(X) Ethernet Port Connection
All TN-5308 models have 8 10/100BaseT(X) Ethernet ports (4-pin shielded
M12 connectors with D coding). The 10/100TX ports located on the
TN-5308’s front panel are used to connect to Ethernet-enabled devices. Most
users configure these ports for Auto MDI/MDI-X mode, in which case the
port’s pinouts are adjusted automatically depending on the type of Ethernet
cable used (straight-through or cross-over), and the type of device (NIC-type
or HUB/Switch-type) connected to the port.
In what follows, we give pinouts for both MDI (NIC-type) ports and MDI-X
(HUB/Switch-type) ports. We also give cable wiring diagrams for
straight-through and cross-over Ethernet cables.
Pinouts for the 10/100BaseT(X) Ports on the TN-5308
Housing: shield
Pinouts for the RJ45 (8-pin) Port
RJ45 (8-Pin)
MDI Port Pinouts
MDI-X Port Pinouts
1
8
Pin Signal
1 Tx
+
2 Tx
-
3 Rx
+
6 Rx
-
Pin Signal
1 Rx
+
2 Rx
-
3 Tx
+
6 Tx
-
M12 (4-pin, M) to M12 (4-pin, M) Cross-Over Cable Wiring
Tx+
Rx+
Tx-
Rx-
Cross-Over Cable Wiring
1
2
3
4
1
2
3
4
Tx+
Rx+
Tx-
Rx-