16.5

Changing the Feed Rollers

Remove the pressure spring with its
fastening screws. The feedroller can
then be pulled out from the side.

Remove the drive gear cover, lift the
drive chain from the sprockets and
pull the sprocket from the shaft.

16.6

Changing the Cutterblock

Remove the drive gear cover and
take the main drive belt off the pulleys.

Take off the cover plate and remove
the three screws holding the
cutterblock bearing.
The cutterblock can now be pulled
out.