Clearances, Height requirements – Monessen Hearth TPB24 User Manual

Page 15

Advertising
background image

70D0004

15

Heater in
Fireplace or
Firebox

Heat
Resistant
Material

10" or less

12" min. 28"

2

1

/

2

"

8"

6"

7"

14

1

/

2

"

4"

Figure 10 - Minimum Mantel Clearance with Hood - TPB24/30

(Example of Unsafe Installation)

Figure 9 - Minimum Mantel Clearance with No Hood — TPB24/30

Example:

The bottom of the mantel may project from the wall a maxi-

mum of 10" at a minimum of 28" above the opening.

CLEARANCES

AND

HEIGHT REQUIREMENTS

Figure 10 is an example of an unsafe mantel installation.
This mantel projects 4" at 8" above the opening, exceeding the
maximum acceptable distance of 2

1

/

2

" The mantel also proj-

ects 7" at 14

1

/

2

" above the opening, exceeding the maximum

acceptable distance of 6".

If your mantel profile is unsafe, you may either:
• Raise the mantel to an acceptable height
OR
• Remove the mantel