Water service/drains – Manitowoc Ice QM30 Series User Manual

Page 13

Advertising
background image

Section 2

Installation Instructions

2-5

Water Service/Drains

WATER SUPPLY
Local water conditions may require treatment of the
water to inhibit scale formation, filter sediment, and
remove chlorine odor and taste.

Important

If you are installing a Manitowoc water filter
system, refer to the Installation Instructions
supplied with the filter system for ice making water
inlet connections.

Follow these guidelines to install water inlet lines:

• Connect to potable water supply only.
• Do not connect the ice machine to a hot water

supply. Be sure all hot water restrictors installed
for other equipment are working. (Check valves
on sink faucets, dishwashers, etc.)

• If water pressure exceeds the maximum

recommended pressure, obtain a water pressure
regulator from your Manitowoc distributor.

• Install a water shut-off valve for the ice making

water lines.

• Insulate water lines to prevent condensation.

DRAIN CONNECTIONS
Follow these guidelines when installing drain lines to
prevent drain water from flowing back into the ice
machine and storage bin:

• Drain lines must have a 2.5 cm (1 inch) drop per

1 meter (40 inches) of run, and must not create
traps.

• The floor drain must be large enough to

accommodate drainage from all drains.

• Insulate the bin drain line to prevent

condensation.

WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONS

CAUTION

Plumbing must conform to state and local codes.

Water

Temperature

Water

Pressure

Ice Machine

Connection

Tubing Size Up to Ice

Machine Fitting

Ice Making

Water Inlet

10°C (50°F) Min.

1

30°C (86°F) Max.

2

2.4 bar (35 psi) Min.

1

6.2 bar (90 psi) Max.

2

3/4” male hose

connection

3

0.95 cm (3/8”)

minimum inside

diameter

Ice Making/Bin

Water Drain

--- ---

1.59 cm (5/8”)

inside diameter

flexible hose

1.59 cm (5/8”)

minimum inside

diameter

1

Min. = Minimum

2

Max. = Maximum

3

A 3/4” by 11-1/2 threads per inch to 14 threads per inch adapter is factory installed. Remove this adapter if 11-1/2 threads per inch

connection is desired.

Advertising