TRIM AND MANTEL INSTALLATION FOR WOOD BURNING FIREPLACES

• The fireplace face may be left exposed or trimmed with

material such as brick, stone, or marble. If trim is installed,

fasten it securely to face of fireplace. Seal any cracks

between trim material and face of fireplace. Cracks can

cause a fire and prevent fireplace from working properly.

Block the fireplace with framing and attach the base to the

supporting floor to reduce the possibility of such a crack

developing.

• Place wall ties in mortar joints of masonry trim. Fasten

wall ties to face of fireplace with sheet metal screws.

• Do not install combustible materials below the top spac-

ers of the fireplace. Do not allow combustible materials to

overlap the sides of fireplace face. Seal face of fireplace

to surrounding wall with noncombustible caulk or trim

materials. This will prevent cold air leaking around the

fireplace. See Figure 23.

• Use only non-combustible materials below top of spac-

ers.

• The trim must not block or restrict in any way the flow of

air through the air inlet and air outlet louvers in the face

of the fireplace.

Seal any space between face of
fireplace and non-combustible facing
material. Failure to seal this crack is a
possible fire hazard and will void the
warranty.

W

ARNING

¾"

Separation

0" Clearance

to Front Side

Walls

LOCATING FRONT AND SIDE CLEARANCES

To find front clearances, extend a line from back corner of unit

to 4" in front of fireplace face and 1" outside screened opening.

Combustible materials may be placed within shaded areas.

Note: Do not let combustible materials overlap black
painted surface more than

1

/

8

".

See Figure 24.

Trim may butt against side walls of fireplace. The other 3 walls

must have ¾" clearances.
To avoid interference with glass doors, do not allow non-

combustible decorative trim to extend closer than

3

/

8

" to the

vertical edges of the firebox opening.

4" Reference

Extended Line

1" Reference

Figure 23 - Spacer Location

Figure 24 - Front and Side Clearances

Combustible Material

within Shaded Area

Combustible

Wallboard

Non-Combustible

Trim

Area to Be

Sealed

Do not block or restrict air inlets or
air outlets. Blocking or restricting air
inlets or air outlets could cause a fire
hazard.

W

ARNING